ALCATEL-IND1-PORT-MIB DEFINITIONS ::= BEGIN

IMPORTS
	OBJECT-TYPE, Counter64,Unsigned32,
        NOTIFICATION-TYPE, MODULE-IDENTITY,
	TimeTicks, Integer32              FROM SNMPv2-SMI
        TimeStamp,RowStatus,DateAndTime,TEXTUAL-CONVENTION 
                         FROM SNMPv2-TC
        MODULE-COMPLIANCE, OBJECT-GROUP,
        NOTIFICATION-GROUP                FROM SNMPv2-CONF
	DisplayString			  FROM SNMPv2-TC
        ifIndex, ifInErrors, ifOutErrors,InterfaceIndex
					  FROM IF-MIB
	SnmpAdminString
					  FROM SNMP-FRAMEWORK-MIB
	softentIND1Port, cmmEsmDrvTraps
			   		  FROM ALCATEL-IND1-BASE;


alcatelIND1PortMIB MODULE-IDENTITY

   LAST-UPDATED  "201910070000Z"
   ORGANIZATION  "ALE USA Inc"
   CONTACT-INFO
        "Please consult with Customer Service to ensure the most appropriate
         version of this document is used with the products in question:

                        Alcatel-Lucent Enterprise,
                           26801 West Agoura Road
                        Agoura Hills, CA  91301-5122
                          United States Of America

        Telephone:               +1 800 995 2696 
 				                 
        Electronic Mail:         ebg_global_supportcenter@al-enterprise.com
        World Wide Web:          https://www.al-enterprise.com"  

    DESCRIPTION
        "This module describes an authoritative enterprise-specific Simple
         Network Management Protocol (SNMP) Management Information Base (MIB):

             This group contains the configuration information data
	     for the Ethernet Switching Module.

         The right to make changes in specification and other information
         contained in this document without prior notice is reserved.

         No liability shall be assumed for any incidental, indirect, special, or
         consequential damages whatsoever arising from or related to this
         document or the information contained herein.

         Vendors, end-users, and other interested parties are granted
         non-exclusive license to use this specification in connection with
         management of the products for which it is intended to be used.

                     Copyright (C) ALE USA Inc. 2014-2019
		     Copyright (C) 1995-2013 Alcatel-Lucent
                     ALL RIGHTS RESERVED WORLDWIDE"

    REVISION	  "200909070000Z"
    DESCRIPTION
	"Added esmSlotInfoTable."

    REVISION      "201910070000Z"
    DESCRIPTION
        "Updated the latest contact and Copyright information for ALE USA Inc."

    ::= { softentIND1Port 1}

alcatelIND1PortNotifications			OBJECT IDENTIFIER ::= { alcatelIND1PortMIB 0 }
alcatelIND1PortMIBObjects 			OBJECT IDENTIFIER ::= { alcatelIND1PortMIB 1 }
alcatelIND1PortMIBConformance 			OBJECT IDENTIFIER ::= { alcatelIND1PortMIB 2 }

--
-- alcatelIND1PortMIBObjects
--

esmConfTrap                                     OBJECT IDENTIFIER ::= { alcatelIND1PortMIBObjects 1 } 
physicalPort                                    OBJECT IDENTIFIER ::= { alcatelIND1PortMIBObjects 2 }
ddmConfiguration                                OBJECT IDENTIFIER ::= { alcatelIND1PortMIBObjects 4 }
esmViolationRecovery                            OBJECT IDENTIFIER ::= { alcatelIND1PortMIBObjects 5 }
esmDBChangeRebootReqdMIBObjects                 OBJECT IDENTIFIER ::= { alcatelIND1PortMIBObjects 6 }
esmStormThresholdViolation                      OBJECT IDENTIFIER ::= { alcatelIND1PortMIBObjects 7 }
alaDBChangeMIBObjects                           OBJECT IDENTIFIER ::= { alcatelIND1PortMIBObjects 8 }
ptpConfiguration                                OBJECT IDENTIFIER ::= { alcatelIND1PortMIBObjects 9 }


ddmNotifications                                OBJECT IDENTIFIER ::= { alcatelIND1PortNotifications 1 }
esmViolationNotifications                       OBJECT IDENTIFIER ::= { alcatelIND1PortNotifications 2 }
 
-- Textual Conventions
AlaDBType ::= TEXTUAL-CONVENTION
        STATUS  current
        DESCRIPTION
		"Specifies the DB type."
	SYNTAX  INTEGER {
			   none (0), -- Indicates DB removed and currently none exists
			   kf2SfpPlusDB (1), -- SFP+ daughter module for Kingfisher2
			   kf2HDMIStackingDB     (2),  -- HDMI stacking daughter module for Kingfisher2
			   kf2RJ45DB (3), -- RJ45 based daughter module for Kingfisher2
			   kf2SfpDB     (4)  -- SFP based daughter module for Kingfisher2
			}

EsmDBType ::= TEXTUAL-CONVENTION
        STATUS  current
        DESCRIPTION
		"Specifies the BD type."
	SYNTAX  INTEGER {
			sfpPlusDaughterModule (1), -- SFP+ daughter module
			cx4StackingModule     (2)  -- CX4 stacking module	
			}

-- Ethernet Driver object related to Trap *********************

esmDrvTrapDrops   OBJECT-TYPE
	SYNTAX  Integer32
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION "Partitioned port (separated due to errors)."
	::= { esmConfTrap 1 }

-- Dying Gasp Trap Object
alaDyingGaspSlot        OBJECT-TYPE
        SYNTAX          Integer32
        MAX-ACCESS      accessible-for-notify
        STATUS          current
        DESCRIPTION
                "This object specifies the slot number of the chassis whose NI is going down."
	::= { esmConfTrap 2 }

alaDyingGaspPowerSupplyType            OBJECT-TYPE
        SYNTAX          INTEGER {
				primary (1),
				backup (2),
                                none (3)
			       }
        MAX-ACCESS      accessible-for-notify
        STATUS          current
        DESCRIPTION
                "This object specifies the type of the power supply."
	::= { esmConfTrap 3 }

alaDyingGaspTime OBJECT-TYPE
        SYNTAX          DateAndTime 
        MAX-ACCESS      accessible-for-notify
        STATUS          current
        DESCRIPTION
                "This object specifies the time of power failure."
	::= { esmConfTrap 4 }

esmPortViolationValue OBJECT-TYPE
       SYNTAX  INTEGER {
              bEniSecurityBlockPortNone(0),        -- No App blocking this port
              bEniSecurityBlockPortENI(1),         -- ENI App blocking this port
              bEniSecurityBlockPortSTP(2),         -- STP App blocking this port
              bEniSecurityBlockPortLPSS(3),        -- LPS Shutdown App blocking this port
              bEniSecurityBlockPortQoS(4),         -- QoS App blocking this port
              bEniSecurityBlockPortUDLD(5),        -- UDLD App blocking this port
              bEniSecurityBlockPortETHBLK(6),      -- ETHBLK App blocking this port
           -- bEniSecurityBlockPortNISUP(7),      
           -- bEniSecurityBlockPortLLDP(8),  
           -- bEniSecurityBlockPortRFP(9),         
           -- bEniSecurityBlockPortLinkMon(10),   
              bEniSecurityBlockPortLFP(11)
           -- bEniSecurityBlockPortLPSD(12) 
			}
        MAX-ACCESS      accessible-for-notify
        STATUS          current
        DESCRIPTION
                "This object contains the mapping of esmPortViolation bitmap to an integeral value."
	::= { esmConfTrap 5 }

-- Ethernet Storm Violation   
 
 esmStormViolationThresholdNotificationType        OBJECT-TYPE   
         SYNTAX                INTEGER    
                                 {   
                                         clearViolation(1),   
                                         hiAlarm(2),   
                                         lowAlarm(3)   
                                 }   
         MAX-ACCESS        accessible-for-notify   
         STATUS                current   
         DESCRIPTION   
                 "This type defines the trap genrated by storm control feature for high or low threshold."   
         ::=        { esmConfTrap 6 } 
    
 esmStormViolationThresholdTrafficType        OBJECT-TYPE   
         SYNTAX                INTEGER    
                                 {   
                                         broadcast(1),   
                                         multicast(2),   
                                         uunicast(3)   
                                 }   
         MAX-ACCESS        accessible-for-notify   
         STATUS                current   
         DESCRIPTION   
                 "This type defines the traffic for which the trap genrated by storm control feature for high or low threshold."   
         ::=        { esmConfTrap 7 }           
            

-- Ethernet Driver Tables *****************************

        --  EsmConf group.  This group contains the configuration
        --  information data for the Ethernet Switching Module.
        --  Implementation of this group is mandantory.
        --
        --  Note that this MIB can NOT be used for row creation (this
        --  would imply that you could override the actual physical
        --  characteristics of the physical card!).

        esmConfTable  OBJECT-TYPE
            SYNTAX  SEQUENCE OF EsmConfEntry
            MAX-ACCESS  not-accessible
            STATUS  current
            DESCRIPTION
                "A list of ESM Physical Port instances."
            ::= { physicalPort 1 }

        esmConfEntry  OBJECT-TYPE
            SYNTAX  EsmConfEntry
            MAX-ACCESS  not-accessible
            STATUS  current
            DESCRIPTION
                "A ESM Physical Port entry."
            INDEX { ifIndex }
            ::= { esmConfTable 1 }

        EsmConfEntry ::= SEQUENCE {
	    esmPortSlot
	        Integer32,
	    esmPortIF
	        Integer32,
            esmPortAutoSpeed
                INTEGER,
            esmPortAutoDuplexMode
                INTEGER,
            esmPortCfgSpeed
                INTEGER,
            esmPortCfgDuplexMode
                INTEGER,
            esmPortCfgIFG
                Integer32,
            esmPortPauseSlotTime
                Integer32,
            esmPortMaxFloodRate
                INTEGER,
            esmPortFloodMcastEnable
                INTEGER,
            esmPortCfgMaxFrameSize
                Integer32,
            esmPortCfgLongEnable
                INTEGER,
            esmPortCfgRuntEnable
                INTEGER,
            esmPortCfgRuntSize
                Integer32,
	    esmPortCfgAutoNegotiation
			INTEGER,
	    esmPortCfgCrossover
			INTEGER,
	    esmPortCfgFlow
			INTEGER,
	    esmPortCfgHybridActiveType
	    		INTEGER,
	    esmPortCfgHybridMode
	    		INTEGER,
            esmPortOperationalHybridType
                        INTEGER,
            esmPortCfgMMULowWaterMarkCellSetLimit
                	INTEGER,
            esmPortCfgMMUDynamicCellSetLimit
                	INTEGER,
            esmPortViolationBitMap
                        BITS,
            esmPortViolationClearAll
                        INTEGER,	    
	    esmPortFloodBcastEnable
		INTEGER,
	    esmPortFloodUnknownUcastEnable
		INTEGER,
	    esmPortMaxUnknownUcastFloodRate
		INTEGER,
	    esmPortMaxMcastFloodRate
		INTEGER,
	    esmPortMaxFloodRateLimit
		Integer32,
	    esmPortMaxUnknownUcastFloodRateLimit
		Integer32,
	    esmPortMaxMcastFloodRateLimit
		Integer32,
            esmPortCfgSFPType
                DisplayString,
	    esmPortWaitToRestoreTimer
                        Integer32,
           esmPortMinFloodRateLimit   
                 Integer32,   
             esmPortMinMcastFloodRateLimit   
                 Integer32,   
             esmPortFloodThresholdAction   
                INTEGER,   
             esmPortMcastThresholdAction   
                 INTEGER,   
             esmPortFlood
	         INTEGER,
	     esmPortMCastStorm
	         INTEGER,
            esmPortCfgEeeStatus
			INTEGER,
            esmPortCfgEeeAutoNegState
                        INTEGER,
            esmPortCfgEeeCapability 
                        INTEGER
            }

        esmPortSlot OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
            "The physical Slot number for this Ethernet Port.
	     Slot number has been added to be used by the private Trap."
        ::= { esmConfEntry 1 }

        esmPortIF OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
            "The on-board interface number for this Ethernet Port.
	     Port Number has been added to be used by the private Trap."
        ::= { esmConfEntry 2 }

        esmPortAutoSpeed OBJECT-TYPE
            SYNTAX INTEGER {
                speed100(1),
                speed10(2),
                speedAuto(3),
                unknown(4),
                speed1000(5),
	        speed10000(6)
            }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
            "The automatically detected port line speed
             of this ESM port."
        ::= { esmConfEntry 3 }

        esmPortAutoDuplexMode OBJECT-TYPE
            SYNTAX INTEGER {
                fullDuplex(1),
                halfDuplex(2),
                autoDuplex(3),
                unknown(4)
            }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
            "The automatically detected port duplex mode
             of this ESM port.

	     Note: GigaEthernet supports only Full duplex mode.
	           Default value for 10/100 = Half duplex mode."
        ::= { esmConfEntry 4 }

        esmPortCfgSpeed OBJECT-TYPE
            SYNTAX INTEGER {
                speed100(1),
                speed10(2),
                speedAuto(3),
                speed1000(5),
	        speed10000(6),
	        speedMax100(8),
		speedMax1000(9)
            }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
            "The configured port line speed of this ESM port."
        ::= { esmConfEntry 5 }

        esmPortCfgDuplexMode OBJECT-TYPE
            SYNTAX INTEGER {
                fullDuplex(1),
                halfDuplex(2),
                autoDuplex(3)
            }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
            "The configured port duplex mode of this ESM port.
            Note: GigaEthernet support only full-duplex."
        ::= { esmConfEntry 6 }

        esmPortCfgIFG OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
            "Contains the setting of Inter-Frame Gap (IFG), in bytes
            for receive and transmit.
	    The range is from 9 to 12 bytes.

	    Note: The default value changed according to the Port type
	    Default    Bandwidth    value
	    12 bytes    10Mbps       9600 nsec
	               100Mbps        960 nsec
	 	         1Gbps         96 nsec
			10Gbps        9.6 nsec."
	    DEFVAL { 12 }
        ::= { esmConfEntry 7 }

        esmPortPauseSlotTime OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
            "Indicates the number of microseconds the other
             end-station waits after the reception
             of a pause frame.

	     Note: Pause Flow control is not available for 10Mbps.
	           For 100Mbps, the possible value range is
		   5120 nanosec to 0.3 sec.
	   	   For 1Gbps, the possible value range is
		   512 nanosec to 0.03 sec."
        ::= { esmConfEntry 8 }

        esmPortMaxFloodRate    OBJECT-TYPE
            SYNTAX INTEGER {
                      mbps(1),
                      percentage(2),
		      pps(3),
		      default(4)
                   }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Broadcast flood threshold type. To set the type, set esmPortMaxFloodRateLimit also.
		 The default value for flood rate is:
                        1. 4 mbps if the port speed is 10 mbps,
                        2. 49 mbps if the port speed is 100 mbps
                        3. 496 mbps if the port speed is 1G
                        4. 997 mbps if the port speed is 10G
                 "
	    DEFVAL { mbps }
          ::= { esmConfEntry 9 }

        esmPortFloodMcastEnable    OBJECT-TYPE
            SYNTAX INTEGER {
                      enableFlood(0),
                      enableMulticastFlood(1),
                      disableMulticastFlood(2)
                   }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Enable/disable the maximum flood rate
                  for multicast."
	    DEFVAL { disableMulticastFlood }
          ::= { esmConfEntry 10 }

        esmPortCfgMaxFrameSize   OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Configure the value of the maximum frame
                  size allow.
		  For 10/100:
		  It is a range between 1518(untagged) and 1553 bytes.
		  For GigaEthernet:
	          It is a range between 1518 and 10240 bytes.(OS7700,OS7800,OS8800)
                  It is a range between 1518 and 9216 bytes.(OS6800)"
          ::= { esmConfEntry 11 }

        esmPortCfgLongEnable   OBJECT-TYPE
            SYNTAX INTEGER {
                disable(0),
                enable(1)
            }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Allow the user to change the maximun Frame size.
                  Note: It is not configurable for 10/100 Ethernet port."
	    DEFVAL { disable }
          ::= { esmConfEntry 12 }

        esmPortCfgRuntEnable   OBJECT-TYPE
            SYNTAX INTEGER {
                disable(2),
                enable(3)
            }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Allow the user to change the minimum Frame size."
	    DEFVAL { disable }
          ::= { esmConfEntry 13 }

        esmPortCfgRuntSize   OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Configure the value of the minimum frame
                  size allow per ports.
		  The range is 0 to 64."
	    DEFVAL { 64 }
          ::= { esmConfEntry 14 }

        esmPortCfgAutoNegotiation   OBJECT-TYPE
            SYNTAX INTEGER {
                enable(1),
                disable(2)
            }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Allow the user to enable or disable the port auto negotiation."
	    DEFVAL { disable }
          ::= { esmConfEntry 15 }

        esmPortCfgCrossover   OBJECT-TYPE
            SYNTAX INTEGER {
                	mdi(1),
                	mdix(2),
			auto(3)
            }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Allow the user to configure port crossover."
	    DEFVAL { auto }
          ::= { esmConfEntry 16 }

        esmPortCfgFlow   OBJECT-TYPE
            SYNTAX INTEGER {
                enable(1),
                disable(2)
            }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Use the dot3PauseAdminMode from the standard MIB to configure the flow control."
	    DEFVAL { disable }
          ::= { esmConfEntry 17 }

 	esmPortCfgHybridActiveType OBJECT-TYPE
            SYNTAX INTEGER {
                notapplicable(0),
                fiber(1),
                copper(2)
            }
            MAX-ACCESS  read-only
            STATUS  current
            DESCRIPTION
                 "This object is only applicable to hybrid ports .
                  It indicates configured active media type.(the operational media
                  type may be different if esmPortCfgHybridMode is configured to be
                  preferredFiber or preferredCopper)
                  For non hybrid ports notapplicable is returned as a status."
          ::= { esmConfEntry 18 }

	esmPortCfgHybridMode OBJECT-TYPE
            SYNTAX INTEGER {
                notapplicable(0),
                preferredCopper(1),
                forcedCopper(2),
                preferredFiber(3),
                forcedFiber(4)
            }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "This object is only applicable to hybrid ports. 
                  This allows the user the user to configure the media type
                  with which the port should come up. 
                  The user can configure the port to come as copper only 
                  or fiber only or either fiber/copper 
                  (with preference to one of them)."
	    DEFVAL { preferredFiber }
          ::= { esmConfEntry 19 }

 	esmPortOperationalHybridType OBJECT-TYPE
            SYNTAX INTEGER {
		none(0),
                fiber(1),
                copper(2)
            }
            MAX-ACCESS  read-only
            STATUS  current
            DESCRIPTION
                 "This object is only applicable to hybrid ports .
                  It indicates  the actual media type that has link up and is or will be
                  passing traffic. If link is not present the object will return none(0) value."
          ::= { esmConfEntry 20 }

	esmPortCfgMMULowWaterMarkCellSetLimit OBJECT-TYPE
	    SYNTAX INTEGER (0..16383)
	    MAX-ACCESS read-write
	    STATUS current
	    DESCRIPTION
		" Per-port-per-CoS Head of Line blocking cell limits. Range is 0 - 16383
		  Firebolt register Offset: 0x006pp30 - 0x37
		  Bits: 13:0 CellSetLimit , Default: 0x0100
		  This setting allocates the guaranteed cells for one port's CoSx queue.
		  After cell count over this limit, it will start using dynamic cells in
		  port dynamic space."
	    DEFVAL { 256 }
	  ::= { esmConfEntry 21 }

	esmPortCfgMMUDynamicCellSetLimit OBJECT-TYPE
	    SYNTAX INTEGER (0..16383)
	    MAX-ACCESS read-write
	    STATUS current
	    DESCRIPTION
		"Per-egress port cell-based dynamic (shared buffer pool) memory
		usage drop and resume thresholds. This sets the limit for which
		the eight CoS-Qs within a port may share once the LWMCOSCELL
		limit is exceeded. Range is 0 - 16383
		Firebolt register Offset: 0x006pp040
		Bits: 13:0 Dynamic CellSetLimit , 
                Chip Default: 0x0400 (1024).
                The system default value for Dynamic CellSetLimit is 0x100 (256)."
	    DEFVAL { 1024 }
	  ::= { esmConfEntry 22 }



      esmPortViolationBitMap OBJECT-TYPE
          SYNTAX      BITS{
		  bEniSecurityBlockPortNONE(0),           --No App blocking this port
                  bEniSecurityBlockPortSTP(1),            --STP App blocking this port
                  bEniSecurityBlockPortLPS-S(2),          --LPS-S App blocking this port
                  bEniSecurityBlockPortQos(3),            --Qos App blocking this port
                  bEniSecurityBlockPortUDLD(4),           --UDLD App blocking this port
                  bEniSecurityBlockPortETHBLK(5),         --ETHBLK App blocking this port
                  bEniSecurityBlockPortNISUP(6),          --NISUP App blocking this port
                  bEniSecurityBlockPortLLDP(7),           --LLDP App blocking this port
                  bEniSecurityBlockPortRFP(8),            --RFP App blocking this port
                  bEniSecurityBlockPortLinkMon(9),       --LinkMon App blocking this port
                  bEniSecurityBlockPortLFP(10),           --LFP App blocking this port
                  bEniSecurityBlockPortLPSD(11),          --LPSD App blocking this port
                  bEniSecurityBlockPortSTROM(12),         --ETHERNET STROM App blocking this port
                  bEniSecurityBlockPortLBD(13),           --LBD App blocking this port
                  bEniSecurityBlockPortSTP-S(14)          --STP-S App blocking this port
       }
          MAX-ACCESS  read-only
          STATUS      current
          DESCRIPTION "A bit map that identifies the set of Application that have blocked 
                       a port as a result of a particular violation "

          ::= { esmConfEntry 23 }

      esmPortViolationClearAll OBJECT-TYPE
          SYNTAX      INTEGER(0) 
          MAX-ACCESS  read-write
          STATUS      current
          DESCRIPTION "Clear all port vioaltion "

          ::= { esmConfEntry 24 }
      

	esmPortFloodBcastEnable    OBJECT-TYPE
            SYNTAX INTEGER {
                      disableBcastFlood(2),
                      enableBcastFlood(1)
                   }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Enable/disable the maximum flood rate
                  for Broadcast."
	    DEFVAL { enableBcastFlood }
          ::= { esmConfEntry 25 }

	esmPortFloodUnknownUcastEnable    OBJECT-TYPE
            SYNTAX INTEGER {
                      disableUnknownUcastFlood(2),
                      enableUnknownUcastFlood(1)
                   }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Enable/disable the maximum flood rate
                  for unknown unicast."
	    DEFVAL { enableUnknownUcastFlood }
          ::= { esmConfEntry 26 }

	esmPortMaxUnknownUcastFloodRate    OBJECT-TYPE
            SYNTAX INTEGER {
                      mbps(1),
                      percentage(2),
		      pps(3),
		      default(4)
                   }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Unknown-Unicast flood threshold type. To set the type, set esmPortMaxUnknownUcastFloodRateLimit also.
		 The default value for flood rate is:
                        1. 4 mbps if the port speed is 10 mbps,
                        2. 49 mbps if the port speed is 100 mbps
                        3. 496 mbps if the port speed is 1G
                        4. 997 mbps if the port speed is 10G
                 "
	    DEFVAL { mbps }
          ::= { esmConfEntry 27 }

	esmPortMaxMcastFloodRate    OBJECT-TYPE
            SYNTAX INTEGER {
                      mbps(1),
                      percentage(2),
		      pps(3),
		      default(4)
                   }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Multicast flood threshold type. To set the type, set esmPortMaxFloodRateLimit also.
		 The default value for flood rate is:
		 	1. 4 mbps if the port speed is 10 mbps,
		 	2. 49 mbps if the port speed is 100 mbps
		 	3. 496 mbps if the port speed is 1G
		 	4. 997 mbps if the port speed is 10G
		 "
	    DEFVAL { mbps }
          ::= { esmConfEntry 28 }

	esmPortMaxFloodRateLimit    OBJECT-TYPE
            SYNTAX  Integer32
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "The value of the maximum broadcast flood limit.
		  The actual range of the flood limit depends on the port speed.
		     example:	
		     Percentage: 1 - 100
		     Mbps: 1 - 1000 (1G speed)
		     PPS: 244 - 244262 (1G speed)
		  To set the limit, set esmPortMaxFloodRate first"
          ::= { esmConfEntry 29 }


	esmPortMaxUnknownUcastFloodRateLimit    OBJECT-TYPE
            SYNTAX  Integer32
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "The value of the maximum unknown-unicast flood limit
		  The actual range of the flood limit depends on the port speed.
		     example:	
		     Percentage: 1 - 100
		     Mbps: 1 - 1000 (1G speed)
		     PPS: 244 - 244262 (1G speed)
		  To set the limit, set esmPortMaxUnknownUcastFloodRate first"
          ::= { esmConfEntry 30 }

       esmPortMaxMcastFloodRateLimit    OBJECT-TYPE
            SYNTAX  Integer32
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "The value of the maximum multicast flood limit
		  The actual range of the flood limit depends on the port speed.
		     example:	
		     Percentage: 1 - 100
		     Mbps: 1 - 1000 (1G speed)
		     PPS: 244 - 244262 (1G speed)
		  To set the limit, set esmPortMaxMcastFloodRate first"
          ::= { esmConfEntry 31 }

      esmPortCfgSFPType OBJECT-TYPE
            SYNTAX      DisplayString (SIZE (0..64))
            MAX-ACCESS read-only
            STATUS      current
            DESCRIPTION
                 "This object is only applicable to fiber ports.
                  The string indicates the type of SFP/GBIC of active media."
          ::= {  esmConfEntry 32 }

      esmPortWaitToRestoreTimer   OBJECT-TYPE
            SYNTAX Integer32 (0..300)
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Indicates the number of seconds after which the link up
                  event is notified to other applications.
                  The timer is started whenever a Link Up is detected on a port being monitored."
            DEFVAL { 0 }
          ::= { esmConfEntry 33 }

       esmPortMinFloodRateLimit    OBJECT-TYPE   
             SYNTAX  Integer32   
             MAX-ACCESS  read-write   
             STATUS  current   
             DESCRIPTION   
                  "The value of the minimum broadcast flood limit   
                    this value should be same type as that of the    
                    maximum value configured for broadcast traffic."   
           ::= { esmConfEntry 34 }   
                    
        esmPortMinMcastFloodRateLimit    OBJECT-TYPE   
            SYNTAX  Integer32   
            MAX-ACCESS  read-write   
            STATUS  current   
            DESCRIPTION   
                 "The value of the minimum multicast flood limit   
                  this value should be same type as that of the    
                  maximum value configured for multicast traffic."   
           ::= { esmConfEntry 35 }   
                    
        esmPortFloodThresholdAction    OBJECT-TYPE   
             SYNTAX  INTEGER {   
                      default (0),   
                      trap (1),   
                      shutdown (2)   
             }   
             MAX-ACCESS  read-write   
             STATUS  current   
             DESCRIPTION   
                  "The action to be taken when the broadcast    
                   traffic exceeding the maximum configured value."   
           DEFVAL { 0 }
           ::= { esmConfEntry 36 }   
                      
         esmPortMcastThresholdAction    OBJECT-TYPE   
             SYNTAX  INTEGER {   
                     default (0),   
                     trap (1),   
                     shutdown (2)   
            }   
          MAX-ACCESS  read-write   
          STATUS  current   
          DESCRIPTION   
          "The action to be taken when the multicast    
           traffic exceeding the maximum configured value."   
          DEFVAL { 0 }
           ::= { esmConfEntry 37 }   
                      
	esmPortFlood 		OBJECT-TYPE   
             SYNTAX  INTEGER {   
			normal(0),
			storm(1)
		}
	 MAX-ACCESS  read-only   
         STATUS  current   
         DESCRIPTION   
         "The state of the port, is it having normal or stormed broad
         cast  traffic."
		   ::= { esmConfEntry  	38}	
		   
        esmPortMCastStorm   OBJECT-TYPE   
        SYNTAX  INTEGER {   
		normal(0),
		storm(1)
	}
	MAX-ACCESS  read-only   
        STATUS  current   
        DESCRIPTION   
         "The state of the port, is it having normal or stormed 
	  mulit cast traffic."
		   ::= { esmConfEntry  	39}
		   
        esmPortCfgEeeStatus  OBJECT-TYPE
            SYNTAX INTEGER {
                enable(1),
                disable(2),
		na(3)
            }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Allow the user to enable or disable the port EEE mode."
            DEFVAL { enable }
          ::= { esmConfEntry 40 }

        esmPortCfgEeeAutoNegState  OBJECT-TYPE
            SYNTAX INTEGER {
                none(0),
		speed10(1),
                speed100(2),
		unknown(3),
		speed1000(4),
		na(5)
            }
            MAX-ACCESS  read-only
            STATUS  current
            DESCRIPTION
                 "Current autoneg state of EEE enabled port."
            DEFVAL { none }
          ::= { esmConfEntry 41 }

        esmPortCfgEeeCapability  OBJECT-TYPE
            SYNTAX INTEGER {
                none(0),
                speed10(1),
                speed100(2),
                speed100Speed1000(3),
                speed1000(4),
		na(5)
            }
            MAX-ACCESS  read-only
            STATUS  current
            DESCRIPTION
                 "Current cpapbility of EEE enabled port."
            DEFVAL { none }
          ::= { esmConfEntry 42 }

	-- Ethernet Port Mode Tables *****************************
        --  EsmPortMode group.  This group contains the configuration
        --  information data for the Ethernet Switching Module.
        --  Implementation of this group is mandantory.
        --
        --  Note that this MIB can NOT be used for row creation (this
        --  would imply that you could override the actual physical
        --  characteristics of the physical card!).
        esmPortModeTable  OBJECT-TYPE
            SYNTAX  SEQUENCE OF EsmPortModeEntry
            MAX-ACCESS  not-accessible
            STATUS  current
            DESCRIPTION
                "A list of ESM Physical Port Mode instances."
            ::= { physicalPort 6 }
        esmPortModeEntry  OBJECT-TYPE
            SYNTAX  EsmPortModeEntry
            MAX-ACCESS  not-accessible
            STATUS  current
            DESCRIPTION
                "A ESM Physical Port Mode entry."
            INDEX { esmPortModeIndex }
            ::= { esmPortModeTable 1 }
        EsmPortModeEntry ::= SEQUENCE {
	    esmPortModeIndex
		INTEGER,
            esmPortRunningMode
                INTEGER,
            esmPortSavedMode
                INTEGER
            }
	esmPortModeIndex OBJECT-TYPE
	    SYNTAX INTEGER (1001..8128)
	    MAX-ACCESS not-accessible
	    STATUS current
	    DESCRIPTION
	    "Valid ni/port values"
	::= { esmPortModeEntry 1 }
        esmPortRunningMode OBJECT-TYPE
            SYNTAX INTEGER {
                uplink(1),
                stackable(2)
            }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
            "Currently configured Etna port 25,26 as 10G uplink user port or stacking port.
             Default is uplink 10G port. User can not set the current mode."
        ::= { esmPortModeEntry 2 }
        esmPortSavedMode OBJECT-TYPE
            SYNTAX INTEGER {
                uplink(1),
                stackable(2)
            }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
            "Next configured Etna port 25,26 as 10G uplink user port or stacking port.
             At boot up, it has the same value as current esmPortRunningMode. It takes some time to
             write to the EEPROM. Have at least more than 7 sec between each write operation"
        ::= { esmPortModeEntry 3 }


          -- The Ethernet Statistics Group
          --
          -- The ethernet statistics group contains statistics
          -- measured by the probe for each monitored interface on
          -- this device.  These statistics take the form of free
          -- running counters that start from zero when a valid entry
          -- is created.
          --
          -- This group currently has statistics defined only for
          -- Ethernet interfaces.  Each alcetherStatsEntry contains
          -- statistics for one Ethernet interface.  The probe must
          -- create one alcetherStats entry for each monitored Ethernet
          -- interface on the device.

          alcetherStatsTable OBJECT-TYPE
              SYNTAX SEQUENCE OF AlcetherStatsEntry
              MAX-ACCESS not-accessible
              STATUS current
              DESCRIPTION
                  "A list of Ethernet statistics entries."
              ::= { physicalPort 2 }

          alcetherStatsEntry OBJECT-TYPE
              SYNTAX AlcetherStatsEntry
              MAX-ACCESS not-accessible
              STATUS current
              DESCRIPTION
                  "A collection of statistics kept for a particular
                  Ethernet interface.  As an example, an instance of the
                  etherStatsPkts object might be named alcetherStatsPkts.1"
              INDEX { ifIndex }
              ::= { alcetherStatsTable 1 }

          AlcetherStatsEntry ::= SEQUENCE {
	      alcetherClearStats		    INTEGER,
	      alcetherLastClearStats                TimeTicks,
              alcetherStatsCRCAlignErrors           Counter64,
              alcetherStatsRxUndersizePkts          Counter64,
              alcetherStatsTxUndersizePkts          Counter64,
              alcetherStatsTxOversizePkts           Counter64,
              alcetherStatsRxJabbers                Counter64,
              alcetherStatsRxCollisions             Counter64,
              alcetherStatsTxCollisions             Counter64,
              alcetherStatsPkts64Octets             Counter64,
              alcetherStatsPkts65to127Octets        Counter64,
              alcetherStatsPkts128to255Octets       Counter64,
              alcetherStatsPkts256to511Octets       Counter64,
              alcetherStatsPkts512to1023Octets      Counter64,
              alcetherStatsPkts1024to1518Octets     Counter64,
              gigaEtherStatsPkts1519to4095Octets    Counter64,
              gigaEtherStatsPkts4096to9215Octets    Counter64,
		alcetherStatsPkts1519to2047Octets 	Counter64,
		alcetherStatsPkts2048to4095Octets 	Counter64,
		alcetherStatsPkts4096Octets 		Counter64,
		alcetherStatsRxGiantPkts 		Counter64,
		alcetherStatsRxDribbleNibblePkts 	Counter64,
		alcetherStatsRxLongEventPkts 		Counter64,
		alcetherStatsRxVlanTagPkts 		Counter64,
		alcetherStatsRxControlPkts 		Counter64,
		alcetherStatsRxLenChkErrPkts 		Counter64,
		alcetherStatsRxCodeErrPkts 		Counter64,
		alcetherStatsRxDvEventPkts 		Counter64,
		alcetherStatsRxPrevPktDropped 	Counter64,
		alcetherStatsTx64Octets 		Counter64,
		alcetherStatsTx65to127Octets 		Counter64,
		alcetherStatsTx128to255Octets 	Counter64,
		alcetherStatsTx256to511Octets 	Counter64,
		alcetherStatsTx512to1023Octets 	Counter64,
		alcetherStatsTx1024to1518Octets 	Counter64,
		alcetherStatsTx1519to2047Octets 	Counter64,
		alcetherStatsTx2048to4095Octets 	Counter64,
		alcetherStatsTx4096Octets 		Counter64,
		alcetherStatsTxRetryCount 		Counter64,
		alcetherStatsTxVlanTagPkts 		Counter64,
		alcetherStatsTxControlPkts 		Counter64,
		alcetherStatsTxLatePkts 		Counter64,
		alcetherStatsTxTotalBytesOnWire 	Counter64,
		alcetherStatsTxLenChkErrPkts 		Counter64,
		alcetherStatsTxExcDeferPkts		Counter64
		}

          alcetherClearStats OBJECT-TYPE
              SYNTAX INTEGER
		{	default(0),
	 		reset(1)
		}
              MAX-ACCESS read-write
              STATUS current
              DESCRIPTION
                  "Used to Clear all Statistics counters.
		   By default, this object contains zero value."
              ::= { alcetherStatsEntry 1 }

          alcetherLastClearStats OBJECT-TYPE
              SYNTAX TimeTicks
	      MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The value of SysUpTime at the time of all
		   the statistics counters are cleared.
		   By default, this object contains a zero value."
              ::= { alcetherStatsEntry 2 }

          alcetherStatsCRCAlignErrors OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets received that
                  had a length (excluding framing bits, but
                  including FCS octets) of between 64 and 1518
                  octets, inclusive, but but had either a bad
                  Frame Check Sequence (FCS) with an integral
                  number of octets (FCS Error) or a bad FCS with
                  a non-integral number of octets (Alignment Error)."
              ::= { alcetherStatsEntry 3 }

          alcetherStatsRxUndersizePkts OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets received that were
                  less than 64 octets long (excluding framing bits,
                  but including FCS octets) and were otherwise well
                  formed."
              ::= { alcetherStatsEntry 4 }

          alcetherStatsTxUndersizePkts OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets transmitted that were
                  less than 64 octets long (excluding framing bits,
                  but including FCS octets) and were otherwise well
                  formed."
              ::= { alcetherStatsEntry 5 }

          alcetherStatsTxOversizePkts OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets transmitted that were
                  longer than 1518 octets long (excluding framing bits,
                  but including FCS octets) and were otherwise well
                  formed."
              ::= { alcetherStatsEntry 6 }

          alcetherStatsRxJabbers OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets received that were
                  longer than 1518 octets (excluding framing bits,
                  but including FCS octets), and had either a bad
                  Frame Check Sequence (FCS) with an integral number
                  of octets (FCS Error) or a bad FCS with a
                  non-integral number of octets (Alignment Error).

                  Note that this definition of jabber is different
                  than the definition in IEEE-802.3 section 8.2.1.5
                  (10BASE5) and section 10.3.1.4 (10BASE2).  These
                  documents define jabber as the condition where any
                  packet exceeds 20 ms.  The allowed range to detect
                  jabber is between 20 ms and 150 ms."
              ::= { alcetherStatsEntry 7 }

          alcetherStatsRxCollisions OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The best estimate of the total number of collisions
                  on this Ethernet segment (in reception).
		  Only for Ethernet Interfaces.

                  The value returned will depend on the location of
                  the RMON probe. Section 8.2.1.3 (10BASE-5) and
                  section 10.3.1.3 (10BASE-2) of IEEE standard 802.3
                  states that a station must detect a collision, in
                  the receive mode, if three or more stations are
                  transmitting simultaneously.  A repeater port must
                  detect a collision when two or more stations are
                  transmitting simultaneously.  Thus a probe placed on
                  a repeater port could record more collisions than a
                  probe connected to a station on the same segment
                  would.

                  Probe location plays a much smaller role when
                  considering 10BASE-T.  14.2.1.4 (10BASE-T) of IEEE
                  standard 802.3 defines a collision as the
                  simultaneous presence of signals on the DO and RD
                  circuits (transmitting and receiving at the same
                  time).  A 10BASE-T station can only detect
                  collisions when it is transmitting.  Thus probes
                  placed on a station and a repeater, should report
                  the same number of collisions.

                  Note also that an RMON probe inside a repeater
                  should ideally report collisions between the
                  repeater and one or more other hosts (transmit
                  collisions as defined by IEEE 802.3k) plus receiver
                  collisions observed on any coax segments to which
                  the repeater is connected."
              ::= { alcetherStatsEntry 8 }

          alcetherStatsTxCollisions OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The best estimate of the total number of collisions
                  on this Ethernet segment (in transmition).
		  Only for Ethernet Interfaces.

                  The value returned will depend on the location of
                  the RMON probe. Section 8.2.1.3 (10BASE-5) and
                  section 10.3.1.3 (10BASE-2) of IEEE standard 802.3
                  states that a station must detect a collision, in
                  the receive mode, if three or more stations are
                  transmitting simultaneously.  A repeater port must
                  detect a collision when two or more stations are
                  transmitting simultaneously.  Thus a probe placed on
                  a repeater port could record more collisions than a
                  probe connected to a station on the same segment
                  would.

                  Probe location plays a much smaller role when
                  considering 10BASE-T.  14.2.1.4 (10BASE-T) of IEEE
                  standard 802.3 defines a collision as the
                  simultaneous presence of signals on the DO and RD
                  circuits (transmitting and receiving at the same
                  time).  A 10BASE-T station can only detect
                  collisions when it is transmitting.  Thus probes
                  placed on a station and a repeater, should report
                  the same number of collisions.

                  Note also that an RMON probe inside a repeater
                  should ideally report collisions between the
                  repeater and one or more other hosts (transmit
                  collisions as defined by IEEE 802.3k) plus receiver
                  collisions observed on any coax segments to which
                  the repeater is connected."
              ::= { alcetherStatsEntry 9 }

          alcetherStatsPkts64Octets OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets (including bad
                  packets) received that were 64 octets in length
                  (excluding framing bits but including FCS octets)."
              ::= { alcetherStatsEntry 10 }

          alcetherStatsPkts65to127Octets OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets (including bad
                  packets) received that were between
                  65 and 127 octets in length inclusive
                  (excluding framing bits but including FCS octets)."
              ::= { alcetherStatsEntry 11 }

          alcetherStatsPkts128to255Octets OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets (including bad
                  packets) received that were between
                  128 and 255 octets in length inclusive
                  (excluding framing bits but including FCS octets)."
              ::= { alcetherStatsEntry 12 }

          alcetherStatsPkts256to511Octets OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets (including bad
                  packets) received that were between
                  256 and 511 octets in length inclusive
                  (excluding framing bits but including FCS octets)."
              ::= { alcetherStatsEntry 13 }

          alcetherStatsPkts512to1023Octets OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets (including bad
                  packets) received that were between
                  512 and 1023 octets in length inclusive
                  (excluding framing bits but including FCS octets)."
              ::= { alcetherStatsEntry 14 }

          alcetherStatsPkts1024to1518Octets OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets (including bad
                  packets) received that were between
                  1024 and 1518 octets in length inclusive
                  (excluding framing bits but including FCS octets).
	          For both Ethernet and GigaEthernet."
              ::= { alcetherStatsEntry 15 }

          gigaEtherStatsPkts1519to4095Octets OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets (including bad
                  packets) received that were between
                  1519 and 4095 octets in length inclusive
                  (excluding framing bits but including FCS octets).
		  Only for GigaEthernet interfaces"
              ::= { alcetherStatsEntry 16 }

          gigaEtherStatsPkts4096to9215Octets OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of packets (including bad
                  packets) received that were between
                  4096 and 9215 octets in length inclusive
                  (excluding framing bits but including FCS octets).
		  Only for GigaEthernet interfaces"
              ::= { alcetherStatsEntry 17 }


		alcetherStatsPkts1519to2047Octets 	OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames(including error packets) received
		   that were between 1519 and 2047 bytes in length inclusive
		   (excluding framing bits but including FCS bytes).
		   "
              ::= { alcetherStatsEntry 18 }

		alcetherStatsPkts2048to4095Octets 	OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames(including error packets) received
		   that were between 2048 and 4095 bytes in length inclusive
		   (excluding framing bits but including FCS bytes).
		   "
              ::= { alcetherStatsEntry 19 }

		alcetherStatsPkts4096Octets 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames(including error packets) received
		   that were greater than or equal to 4096 bytes in length inclusive
		   (excluding framing bits but including FCS bytes).
		   "
              ::= { alcetherStatsEntry 20 }

		alcetherStatsRxGiantPkts 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames that are greater than the specified
		   Max length value, with a valid CRC, dropped because too long.
		   "
              ::= { alcetherStatsEntry 21 }

		alcetherStatsRxDribbleNibblePkts 	OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames for which a dribble nibble has been
		   received and CRC is correct.
		   "
              ::= { alcetherStatsEntry 22 }

		alcetherStatsRxLongEventPkts 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames for which the Carrier sense exceeds
		   50000 bit times for 10 Mbits/sec or 80000 bit times for
		   100 Mbits/sec."
              ::= { alcetherStatsEntry 23 }

		alcetherStatsRxVlanTagPkts 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames for which Type/Length field
		   contains the VLAN protocol identifier (0x8100). "
              ::= { alcetherStatsEntry 24 }

		alcetherStatsRxControlPkts 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames that were recognized as control frames."
              ::= { alcetherStatsEntry 25 }

		alcetherStatsRxLenChkErrPkts 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames for which the frame length field value
		   in the Type/Length field does not match the actual data bytes
		    length and is NOT a type field."
              ::= { alcetherStatsEntry 26 }

		alcetherStatsRxCodeErrPkts 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames for which one or more nibbles were
		   signaled as errors during reception of the frame."
              ::= { alcetherStatsEntry 27 }

		alcetherStatsRxDvEventPkts 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames for which a RX_DV event (packet not
		   too long enough to be valid packet) has been seen before the
		    correct frame."
              ::= { alcetherStatsEntry 28 }

		alcetherStatsRxPrevPktDropped 	OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames for which a packet has been dropped
		   (because of too small IFG) before the correct frame."
              ::= { alcetherStatsEntry 29 }

		alcetherStatsTx64Octets 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames of 64 bytes."
              ::= { alcetherStatsEntry 30 }

		alcetherStatsTx65to127Octets 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames that were between
		   65 and 127 bytes in length inclusive (excluding framing bits
		    but including FCS bytes)."
              ::= { alcetherStatsEntry 31 }

		alcetherStatsTx128to255Octets 	OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames that were between
		   128 and 255 bytes in length inclusive (excluding framing bits
		    but including FCS bytes)."
              ::= { alcetherStatsEntry 32 }

		alcetherStatsTx256to511Octets 	OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames that were between
		   256 and 511 bytes in length inclusive (excluding framing bits
		    but including FCS bytes)."
              ::= { alcetherStatsEntry 33 }

		alcetherStatsTx512to1023Octets 	OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames that were between
		   512 and 1023 bytes in length inclusive (excluding framing bits
		    but including FCS bytes)."
              ::= { alcetherStatsEntry 34 }

		alcetherStatsTx1024to1518Octets 	OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames that were between
		   1024 and 1518 bytes in length inclusive (excluding framing bits
		    but including FCS bytes)."
              ::= { alcetherStatsEntry 35 }

		alcetherStatsTx1519to2047Octets 	OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames that were between
		   1519 and 2047 bytes in length inclusive (excluding framing bits
		    but including FCS bytes)."
              ::= { alcetherStatsEntry 36 }

		alcetherStatsTx2048to4095Octets 	OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames that were between
		   2048 and 4095 bytes in length inclusive (excluding framing bits
		    but including FCS bytes)."
              ::= { alcetherStatsEntry 37 }

		alcetherStatsTx4096Octets 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames that were greater than
		    or equal to 4096 bytes in length and less than Max frame length
		    (excluding framing bits but including FCS bytes)."
              ::= { alcetherStatsEntry 38 }

		alcetherStatsTxRetryCount 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of collisions that the frames faced during
		   transmission attempts."
              ::= { alcetherStatsEntry 39 }

		alcetherStatsTxVlanTagPkts 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames for which Type/Length field contains the
		   VLAN protocol identifier (0x8100)."
              ::= { alcetherStatsEntry 40 }

		alcetherStatsTxControlPkts 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames that were recognised as control frames."
              ::= { alcetherStatsEntry 41 }

		alcetherStatsTxLatePkts 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of late collisions that occured beyond the collision window."
              ::= { alcetherStatsEntry 42 }

		alcetherStatsTxTotalBytesOnWire 	OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of bytes transmitted on wire, including all bytes from collided
		  attempts."
              ::= { alcetherStatsEntry 43 }

		alcetherStatsTxLenChkErrPkts 		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of transmitted frames for which the frame length field value
		  in the Type/Length field does not match the actual data bytes length and
		   is NOT a Type field."
              ::= { alcetherStatsEntry 44 }

		alcetherStatsTxExcDeferPkts		OBJECT-TYPE
              SYNTAX Counter64
              MAX-ACCESS read-only
              STATUS current
              DESCRIPTION
                  "The total number of frames that were deferred in excess of 6071 nibble-times
		   in 100 Mbps, 24287 bit-times in 10 Mbps mode. These frames are dropped.(This
		   stat is only in case of Half duplex and excessive defer bit reset)."
              ::= { alcetherStatsEntry 45 }

-- 10 GIG specifics parameters

         alcether10GigTable OBJECT-TYPE
              SYNTAX SEQUENCE OF Alcether10GigEntry
              MAX-ACCESS not-accessible
              STATUS current
              DESCRIPTION
                  "A list of 10 Gig specifics entries."
              ::= { physicalPort 4 }

	alcether10GigEntry OBJECT-TYPE
              SYNTAX Alcether10GigEntry
              MAX-ACCESS not-accessible
              STATUS current
              DESCRIPTION
                  "This table will be populated with the 10 gig only entries.
                  The management interface can use it to specify if A or B is the primary."
              INDEX { ifIndex }
              ::= { alcether10GigTable 1 }

          Alcether10GigEntry ::= SEQUENCE {
	      alcether10GigPrimary	    INTEGER
	      }

	  alcether10GigPrimary OBJECT-TYPE
              SYNTAX INTEGER
		{	phyAprimary(1),
	 		phyBprimary(2),
	 		notApplicable(3)
		}
              MAX-ACCESS read-write
              STATUS current
              DESCRIPTION
                  "Setting the object to 1 will make phy A as primary, 2- phy B as pirmary.
                  Value 3 should not be set. "
              ::= { alcether10GigEntry 1 }

-- End of 10 GIG specifics parameters

esmTdrPortTable OBJECT-TYPE
        SYNTAX          SEQUENCE OF EsmTdrPortEntry
        MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION
                "The table lists the results of cable diagnostics."
        ::= {physicalPort 7 }
esmTdrPortEntry OBJECT-TYPE
        SYNTAX          EsmTdrPortEntry
        MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION
                "An entry corresponding to each port."
        INDEX           { ifIndex }
        ::= { esmTdrPortTable 1 }

EsmTdrPortEntry ::= SEQUENCE {
                                esmTdrPortCableState   			INTEGER,
                                esmTdrPortValidPairs    		Unsigned32,
                                esmTdrPortPair1State    		INTEGER,
                                esmTdrPortPair1Length   		Unsigned32,
                                esmTdrPortPair2State    		INTEGER,
                                esmTdrPortPair2Length   		Unsigned32,
                                esmTdrPortPair3State    		INTEGER,
                                esmTdrPortPair3Length   		Unsigned32,
                                esmTdrPortPair4State  	 	 	INTEGER,
                                esmTdrPortPair4Length  		 	Unsigned32,
                                esmTdrPortFuzzLength   		 	Unsigned32,
                                esmTdrPortTest          		INTEGER,
                                esmTdrClearStats        		INTEGER,
                                esmTdrResult				INTEGER,
                                esmTdrPortExtSwapTypeChannel1		INTEGER,
                                esmTdrPortExtSwapTypeChannel2		INTEGER,
                                esmTdrPortExtPolaritySwapPair1		INTEGER,
                                esmTdrPortExtPolaritySwapPair2		INTEGER,
                                esmTdrPortExtPolaritySwapPair3		INTEGER,
                                esmTdrPortExtPolaritySwapPair4		INTEGER,
                                esmTdrPortExtSkewPair1			Unsigned32,	
                                esmTdrPortExtSkewPair2			Unsigned32,	
                                esmTdrPortExtSkewPair3			Unsigned32,
                                esmTdrPortExtSkewPair4			Unsigned32,
                                esmTdrPortExtAccurateCableLenPair1	Unsigned32,
                                esmTdrPortExtAccurateCableLenPair2	Unsigned32,
                                esmTdrPortExtAccurateCableLenPair3	Unsigned32,
                                esmTdrPortExtAccurateCableLenPair4	Unsigned32,
                                esmTdrPortExtDownshiftStatus		INTEGER,
                                esmTdrExtResult				INTEGER,
                                esmTdrCableLen				Unsigned32,
                                esmTdrPhyType				Unsigned32
                             }
esmTdrPortCableState    OBJECT-TYPE
        SYNTAX          INTEGER{
                                 ok(0),
                                 open(1),
                                 short(2),
                                 openShort(3),
                                 crossTalk(4),
                                 unknown(5),
				 impedanceMismatch(6),
				 shortWithPair1(7),
				 shortWithPair2(8),
				 shortWithPair3(9),
				 shortWithPair4(10)
                                }
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "State of a cable as returned by the TDR test."
        ::= { esmTdrPortEntry 1 }
esmTdrPortValidPairs    OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The number of pairs in the cable for which the results of this test are valid."
        ::= { esmTdrPortEntry 2 }
esmTdrPortPair1State    OBJECT-TYPE
        SYNTAX          INTEGER{
                                 ok(0),
                                 open(1),
                                 short(2),
                                 openShort(3),
                                 crossTalk(4),
                                 unknown(5),
				 impedanceMismatch(6),
				 shortWithPair1(7),
				 shortWithPair2(8),
				 shortWithPair3(9),
				 shortWithPair4(10)
                                }
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The state for pair-1 of the cable as returned by the TDR test."
        ::= { esmTdrPortEntry 3 }
esmTdrPortPair1Length   OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The length for pair-1 of the cable at which the fault is detected if the pair is faulty, complete length of the cable otherwise."
        ::= { esmTdrPortEntry 4 }
esmTdrPortPair2State    OBJECT-TYPE
        SYNTAX          INTEGER{
                                 ok(0),
                                 open(1),
                                 short(2),
                                 openShort(3),
                                 crossTalk(4),
                                 unknown(5),
				 impedanceMismatch(6),
				 shortWithPair1(7),
				 shortWithPair2(8),
				 shortWithPair3(9),
				 shortWithPair4(10)
                                }
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The state for pair-2 of the cable as returned by the TDR test."
        ::= { esmTdrPortEntry 5 }
esmTdrPortPair2Length   OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The length for pair-2 of the cable at which the fault is detected if the pair is faulty, complete length of the cable otherwise."
        ::= { esmTdrPortEntry 6 }
esmTdrPortPair3State    OBJECT-TYPE
        SYNTAX          INTEGER{
                                 ok(0),
                                 open(1),
                                 short(2),
                                 openShort(3),
                                 crossTalk(4),
                                 unknown(5),
				 impedanceMismatch(6),
				 shortWithPair1(7),
				 shortWithPair2(8),
				 shortWithPair3(9),
				 shortWithPair4(10)
                                }
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The state for pair-3 of the cable as returned by the TDR test."
        ::= { esmTdrPortEntry 7 }
esmTdrPortPair3Length   OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The length for pair-3 of the cable at which the fault is detected if the pair is faulty, complete length of the cable otherwise."
        ::= { esmTdrPortEntry 8 }
esmTdrPortPair4State    OBJECT-TYPE
        SYNTAX          INTEGER{
                                 ok(0),
                                 open(1),
                                 short(2),
                                 openShort(3),
                                 crossTalk(4),
                                 unknown(5),
				 impedanceMismatch(6),
				 shortWithPair1(7),
				 shortWithPair2(8),
				 shortWithPair3(9),
				 shortWithPair4(10)
                                }
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The state for pair-4 of the cable as returned by the TDR test."
        ::= { esmTdrPortEntry 9 }
esmTdrPortPair4Length   OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The length for pair-4 of the cable at which the fault is detected if the pair is faulty, complete length of the cable otherwise."
        ::= { esmTdrPortEntry 10 }
esmTdrPortFuzzLength    OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The error in the estimated length of the cable (as returned by TDR test)."
        ::= { esmTdrPortEntry 11 }
esmTdrPortTest          OBJECT-TYPE
        SYNTAX          INTEGER{
                                 off(0),
                                 on(1),
                                 extendedOn(2)
                                }
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                "Object used to start a TDR test or EXTENDED test on the port. When configured as on, it initiates a TDR test on the port. When configured as extendedOn, it initiates a EXTENDED test on the port. A read operation on this object always returns the value off."
        ::= { esmTdrPortEntry 12 }
esmTdrClearStats OBJECT-TYPE
              SYNTAX INTEGER
		{	default(0),
	 		reset(1),
	 		extendedReset(2)
		}
              MAX-ACCESS read-write
              STATUS     current
              DESCRIPTION
                  "Used to Clear TDR stats or EXTENDED stats.
		   By default, this object contains zero value."
              ::= { esmTdrPortEntry 13 }
esmTdrResult	OBJECT-TYPE
              SYNTAX INTEGER
		{
			success(0),
	 		fail(1),
			unknown(2)
		}
              MAX-ACCESS read-only
              STATUS     current
              DESCRIPTION
                  "Used to give the status of API,whether API able to execute TDR test successfully or failed to executethe TDR test."
              ::= { esmTdrPortEntry 14 }
esmTdrPortExtSwapTypeChannel1   OBJECT-TYPE
        SYNTAX          INTEGER{
					straightcable(0),
					crossovercable(1),
					swapnotapplicable(2)
                               }
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "Determines the channel associated with the MDI pair(cross or not for each two MDI pairs)"
        ::= { esmTdrPortEntry 15 }
esmTdrPortExtSwapTypeChannel2   OBJECT-TYPE
        SYNTAX          INTEGER{
					straightcable(0),
					crossovercable(1),
					swapnotapplicable(2)
                               }
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "Determines the channel associated with the MDI pair(cross or not for each two MDI pairs)"
        ::= { esmTdrPortEntry 16}
		
esmTdrPortExtPolaritySwapPair1   OBJECT-TYPE
        SYNTAX          INTEGER{
					positivepolarity(0),
					negativepolarity(1),
					polaritynotapplicable(2)
                               }
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "Detects if the pairs connected with reverse polarity(reverse on one side between two conductors in one pair"
        ::= { esmTdrPortEntry 17 }
esmTdrPortExtPolaritySwapPair2   OBJECT-TYPE
        SYNTAX          INTEGER{
					positivepolarity(0),
					negativepolarity(1),
					polaritynotapplicable(2)
                               }
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "Detects if the pairs connected with reverse polarity(reverse on one side between two conductors in one pair"
        ::= { esmTdrPortEntry 18 }
esmTdrPortExtPolaritySwapPair3   OBJECT-TYPE
        SYNTAX          INTEGER{
					positivepolarity(0),
					negativepolarity(1),
					polaritynotapplicable(2)
                               }
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "Detects if the pairs connected with reverse polarity(reverse on one side between two conductors in one pair"
        ::= { esmTdrPortEntry 19 }
		
esmTdrPortExtPolaritySwapPair4   OBJECT-TYPE
        SYNTAX          INTEGER{
					positivepolarity(0),
					negativepolarity(1),
					polaritynotapplicable(2)
                               }
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "Detects if the pairs connected with reverse polarity(reverse on one side between two conductors in one pair"
        ::= { esmTdrPortEntry 20 }
esmTdrPortExtSkewPair1   OBJECT-TYPE
	SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The Skew among the four pairs of cable(delay  between pairs, in n-Seconds)"
        ::= { esmTdrPortEntry 21 }
esmTdrPortExtSkewPair2   OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The Skew among the four pairs of cable(delay  between pairs, in n-Seconds)"
        ::= { esmTdrPortEntry 22 }
esmTdrPortExtSkewPair3   OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The Skew among the four pairs of cable(delay  between pairs, in n-Seconds)"
        ::= { esmTdrPortEntry 23 }
esmTdrPortExtSkewPair4   OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The Skew among the four pairs of cable(delay  between pairs, in n-Seconds)"
        ::= { esmTdrPortEntry 24 }
esmTdrPortExtAccurateCableLenPair1	OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The Length of the cable in meters"
        ::= { esmTdrPortEntry 25 }
esmTdrPortExtAccurateCableLenPair2	OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The Length of the cable in meters"
        ::= { esmTdrPortEntry 26 }
esmTdrPortExtAccurateCableLenPair3	OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The Length of the cable in meters"
        ::= { esmTdrPortEntry 27 }
esmTdrPortExtAccurateCableLenPair4	OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The Length of the cable in meters"
        ::= { esmTdrPortEntry 28 }
		
esmTdrPortExtDownshiftStatus   OBJECT-TYPE
        SYNTAX          INTEGER{
					nodownshift(0),
					downshiftoccurs(1),
					notapplicable(2)
				}
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "list downshift status of the port"
        ::= { esmTdrPortEntry 29 }
esmTdrExtResult	OBJECT-TYPE
        SYNTAX  INTEGER
		{
			success(0),
	 		fail(1),
			unknown(2)
		}
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
               "Used to give the status of API,whether API able to execute TDR Extended test successfully or failed to execute the TDR Extended test."
        ::= { esmTdrPortEntry 30 }
esmTdrCableLen      OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The Approximate Length of a normal cable(Non-Faulty)"
        ::= { esmTdrPortEntry 31 }
 
esmTdrPhyType      OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "Lists the Marvell types"
        ::= { esmTdrPortEntry 32 }
-- End of TDR Table


-- Ethernet Driver Tables *****************************

        --  EsmHybridConf table contains the configuration
        --  information about the configured inactive media for the 
        --  hybrid port only.
        --  Implementation of this group is mandantory.
        --
        --  Note that entries in this MIB Table can NOT be created by the user, only modified


        esmHybridConfTable  OBJECT-TYPE
            SYNTAX  SEQUENCE OF EsmHybridConfEntry
            MAX-ACCESS  not-accessible
            STATUS  current
            DESCRIPTION
                "A list of inactive hybrid port instances."
            ::= { physicalPort 3 }

        esmHybridConfEntry  OBJECT-TYPE
            SYNTAX  EsmHybridConfEntry
            MAX-ACCESS  not-accessible
            STATUS  current
            DESCRIPTION
                "A ESM Physical Port entry."
            INDEX { ifIndex }
            ::= { esmHybridConfTable 1 }

        EsmHybridConfEntry ::= SEQUENCE {
            esmHybridPortCfgSpeed
                INTEGER,
            esmHybridPortCfgDuplexMode
                INTEGER,
	    esmHybridPortCfgAutoNegotiation
			INTEGER,
	    esmHybridPortCfgCrossover
			INTEGER,
	    esmHybridPortCfgFlow
			INTEGER,
            esmHybridPortCfgInactiveType
			INTEGER,
            esmHybridPortCfgSFPType
                       DisplayString
            }

        esmHybridPortCfgSpeed OBJECT-TYPE
            SYNTAX INTEGER {
                speed100(1),
                speed10(2),
                speedAuto(3),
                speed1000(5),
	        speed10000(6),
	        speedMax100(8),
		speedMax1000(9)
            }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
            "The configured port line speed of this ESM port."
        ::= { esmHybridConfEntry 1 }

        esmHybridPortCfgDuplexMode OBJECT-TYPE
            SYNTAX INTEGER {
                fullDuplex(1),
                halfDuplex(2),
                autoDuplex(3)
            }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
            "The configured port duplex mode of this ESM port.
            Note: GigaEthernet support only full-duplex."
        ::= { esmHybridConfEntry 2 }

        esmHybridPortCfgAutoNegotiation   OBJECT-TYPE
            SYNTAX INTEGER {
                enable(1),
                disable(2)
            }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Allow the user to enable or disable the port auto negotiation."
	    DEFVAL { disable }
          ::= { esmHybridConfEntry 3 }

        esmHybridPortCfgCrossover   OBJECT-TYPE
            SYNTAX INTEGER {
                	mdi(1),
                	mdix(2),
			auto(3)
            }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Allow the user to configure port crossover."
	    DEFVAL { auto }
          ::= { esmHybridConfEntry 4 }

        esmHybridPortCfgFlow   OBJECT-TYPE
            SYNTAX INTEGER {
                disable(1),
		enabledXmit(2),
                enabledRcv(3),
                enabledXmitAndRcv(4)
            }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "This object is used for flow control of hybrid ports. It is similar to the dot3PauseAdminMode
		  object in dot3PauseTable. It is used to configure pause for fiber media."
	    DEFVAL { disable }
          ::= { esmHybridConfEntry 5 }

 	esmHybridPortCfgInactiveType OBJECT-TYPE
            SYNTAX INTEGER {
                fiber(1),
                copper(2)
            }
            MAX-ACCESS  read-only
            STATUS  current
            DESCRIPTION
                 "This object is only applicable to hybrid ports .
                  It indicates the configured inactive media type."
          ::= { esmHybridConfEntry 6 }

esmHybridPortCfgSFPType OBJECT-TYPE
            SYNTAX      DisplayString (SIZE (0..64))
            MAX-ACCESS read-only
            STATUS      current
            DESCRIPTION
                "This object is only applicable to fiber ports.
                The string indicates the type of SFP/GBIC of active media."
          ::= { esmHybridConfEntry 7 }


-- End-to-End Flow Vlan Configuration *****************

-- esmE2EFlowVlan OBJECT-TYPE
            -- SYNTAX INTEGER (0 .. 4094)
            -- MAX-ACCESS read-write
            -- STATUS current
            -- DESCRIPTION
                -- "0 - Deleting End-to-End flow control
                 -- 1-4094 - Enable End-to-End flow control and use the Vlan configured as for End-to-End flow"
            -- ::= { alcatelIND1PortMIBObjects 3 }


-- Digital Diagnostics Monitoring (DDM) **************************

ddmConfig OBJECT-TYPE
	SYNTAX		INTEGER {
					enable(1),
					disable(2)
				}
	MAX-ACCESS	read-write
	STATUS		current
	DESCRIPTION
		"This object enables/disables DDM software feature in the system."
	DEFVAL		{ disable }
	::= { ddmConfiguration 1 }

ddmTrapConfig OBJECT-TYPE
	SYNTAX		INTEGER {
					enable(1),
					disable(2)
				}
	MAX-ACCESS	read-write
	STATUS		current
	DESCRIPTION
		"This objects enables/disables traps for DDM warning/alarm threshold violations."
	DEFVAL		{ disable }
	::= { ddmConfiguration 2 }
ddmNotificationType	OBJECT-TYPE
	SYNTAX		INTEGER
				{
					clearViolation(1),
					highAlarm(2),
					highWarning(3),
					lowWarning(4),
					lowAlarm(5)
				}
	MAX-ACCESS	accessible-for-notify
	STATUS		current
	DESCRIPTION
		"This object defines the trap type for monitored DDM parameters."
	::=	{ ddmConfiguration 3 }

-- ESM per slot information table to get Port information

esmSlotInfoTable  OBJECT-TYPE
            SYNTAX  SEQUENCE OF EsmSlotInfoEntry
            MAX-ACCESS  not-accessible
            STATUS  current
            DESCRIPTION
                "ESM Slot information table."
            ::= { physicalPort 12 }

        esmSlotInfoEntry  OBJECT-TYPE
            SYNTAX  EsmSlotInfoEntry 
            MAX-ACCESS  not-accessible
            STATUS  current
            DESCRIPTION
                "A ESM Physical slot entry."
            INDEX { esmSlotNumber }
            ::= { esmSlotInfoTable 1 }

        EsmSlotInfoEntry   ::= SEQUENCE {
            esmSlotNumber 
                INTEGER,
            esmNumberOfUserPorts
                INTEGER
        }

         esmSlotNumber  OBJECT-TYPE
            SYNTAX INTEGER 
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
            "The slot number on stack."
            ::= { esmSlotInfoEntry  1 }


          esmNumberOfUserPorts OBJECT-TYPE
            SYNTAX INTEGER
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
            "The number of user ports on specified slot number."
            ::= { esmSlotInfoEntry  2 }
-- esmViolationRecoveryTime Configuration *****************

esmViolationRecoveryTrap OBJECT-TYPE
	SYNTAX		INTEGER {
					enable(1),
					disable(2)
				}
	MAX-ACCESS	read-write
	STATUS		current
	DESCRIPTION
		"This objects enables/disables traps for user-port shutdown"
	DEFVAL		{ disable }
	::= { esmViolationRecovery 1 }


esmViolationRecoveryTime OBJECT-TYPE
	    SYNTAX Integer32 (0 .. 600)
	    MAX-ACCESS read-write
	    STATUS current
	    DESCRIPTION
		"0 - Disable the timer
		30 - 600 - timeout value to re-enable the UserPort ports"
	    ::= { esmViolationRecovery 2 }

esmViolationRecoveryNotificationType	OBJECT-TYPE
	SYNTAX		INTEGER
				{
					clearViolation(1),
					recoveryTimer(2),
					adminRecovery(3),
					lfpRecovery(4)
					-- rfpRecovery(5)
				}
	MAX-ACCESS	accessible-for-notify
	STATUS		current
	DESCRIPTION
		"This object defines the trap type for monitored violation-recovery parameters."
	::=	{ esmViolationRecovery 3 }

esmViolationRecoveryMaximum OBJECT-TYPE
    SYNTAX Integer32 (0 .. 50)
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        "0 - recovery mechanism is disabled
         1 - 50 - The maximum number of recovery attempts before a port is shudown."
    DEFVAL { 10 } 	
    ::= { esmViolationRecovery 4 }

alaPortViolationRecoveryTable OBJECT-TYPE
    SYNTAX SEQUENCE OF AlaPortViolationRecoveryEntry
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
        "A list of Interface Violation Recovery Configuration Parameters"
    ::= { esmViolationRecovery 5 }


alaPortViolationRecoveryEntry OBJECT-TYPE
    SYNTAX AlaPortViolationRecoveryEntry
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
        "A collection of Interface Violation Recovery configurations kept for a particular
         Ethernet interface."
    INDEX { ifIndex }
    ::= { alaPortViolationRecoveryTable 1 }

AlaPortViolationRecoveryEntry ::= SEQUENCE
    {
         alaPortViolationRecoveryTime       Integer32,
         alaPortViolationRecoveryMaximum    Integer32
    }

alaPortViolationRecoveryTime OBJECT-TYPE
    SYNTAX Integer32 (-1 .. 600)
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "-1 - value in scalar object esmViolationRecoveryTime
         0  - Disable the timer
         30 - 600 - timeout value to re-enable the ports that have been shutdown"
    DEFVAL { -1 }
    ::= { alaPortViolationRecoveryEntry 1}

alaPortViolationRecoveryMaximum OBJECT-TYPE
    SYNTAX Integer32 (-1 .. 50)
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "-1 - value in scalar object esmViolationRecoveryMaximum
         0  - recovery mechanism is disabled
         1  - 50 - The maximum number of recovery attempts before a port is shudown."
    DEFVAL { -1 }
    ::= { alaPortViolationRecoveryEntry 2}

ddmInfoTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF DdmEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The ddmInfoTable has an entry for each SFP/XFP in the
         system that supports Digital Diagnostic Monitoring (DDM). The table is
         indexed by ifIndex. Each row in this table is dynamically added
         and removed internally by the system based on the presence or absence
         of DDM capable SFP/XFP components."
    ::= { physicalPort 5 }

ddmInfoEntry OBJECT-TYPE
    SYNTAX      DdmEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each row represents a particular SFP/XFP that supports Digital
         Diagnostic Monitoring.
         Entries are created and deleted internally by the system."
    INDEX { ifIndex }
    ::= { ddmInfoTable 1}

DdmEntry ::= SEQUENCE
    {
        ddmTemperature                   Integer32,
        ddmTempLowWarning                Integer32,
        ddmTempLowAlarm                  Integer32,
        ddmTempHiWarning                 Integer32,
        ddmTempHiAlarm                   Integer32,
        ddmSupplyVoltage                 Integer32,
        ddmSupplyVoltageLowWarning       Integer32,
        ddmSupplyVoltageLowAlarm         Integer32,
        ddmSupplyVoltageHiWarning        Integer32,
        ddmSupplyVoltageHiAlarm          Integer32,
        ddmTxBiasCurrent                 Integer32,
        ddmTxBiasCurrentLowWarning       Integer32,
        ddmTxBiasCurrentLowAlarm         Integer32,
        ddmTxBiasCurrentHiWarning        Integer32,
        ddmTxBiasCurrentHiAlarm          Integer32,
        ddmTxOutputPower                 Integer32,
        ddmTxOutputPowerLowWarning       Integer32,
        ddmTxOutputPowerLowAlarm         Integer32,
        ddmTxOutputPowerHiWarning        Integer32,
        ddmTxOutputPowerHiAlarm          Integer32,
        ddmRxOpticalPower                Integer32,
        ddmRxOpticalPowerLowWarning      Integer32,
        ddmRxOpticalPowerLowAlarm        Integer32,
        ddmRxOpticalPowerHiWarning       Integer32,
        ddmRxOpticalPowerHiAlarm         Integer32
    }

ddmTemperature                 OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -150000..150000)
	UNITS		"thousandth of a degree celcius"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTemperature indicates the current temperature
         of the SFP/XFP in 1000s of degrees Celsius.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 1 }

ddmTempLowWarning              OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -150000..150000)
	UNITS       "thousandth of a degree celcius"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTempLowWarning indicates the temperature
         of the SFP/XFP in 1000s of degrees Celsius that triggers a low-warning.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 2 }

ddmTempLowAlarm                OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -150000..150000)
	UNITS       "thousandth of a degree celcius"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTempLowAlarm indicates the temperature
         of the SFP/XFP in 1000s of degrees Celsius that triggers a low-alarm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 3 }

ddmTempHiWarning               OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -150000..150000)
	UNITS       "thousandth of a degree celcius"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTempHiWarning indicates the temperature
         of the SFP/XFP in 1000s of degrees Celsius that triggers a hi-warning.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 4 }

ddmTempHiAlarm                 OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -150000..150000)
	UNITS       "thousandth of a degree celcius"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTempHiAlarm indicates the temperature
         of the SFP/XFP in 1000s of degrees Celsius that triggers a hi-alarm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 5 }

ddmSupplyVoltage               OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | 0..10000)
	UNITS       "thousandth of a volt"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmSupplyVoltage indicates the current supply
         voltage of the SFP/XFP in 1000s of Volts (V).
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 6 }

ddmSupplyVoltageLowWarning     OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | 0..10000)
	UNITS       "thousandth of a volt"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmSupplyVoltageLowWarning indicates the supply
         voltage of the SFP/XFP in 1000s of Volts (V) that triggers a low-warning.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 7 }

ddmSupplyVoltageLowAlarm       OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | 0..10000)
	UNITS       "thousandth of a volt"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmSupplyVoltageLowAlarm indicates the supply
         voltage of the SFP/XFP in 1000s of Volts (V) that triggers a low-alarm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 8 }

ddmSupplyVoltageHiWarning      OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | 0..10000)
	UNITS       "thousandth of a volt"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmSupplyVoltageHiWarning indicates the supply
         voltage of the SFP/XFP in 1000s of Volts (V) that triggers a hi-warning.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 9 }

ddmSupplyVoltageHiAlarm        OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | 0..10000)
	UNITS       "thousandth of a volt"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmSupplyVoltageHiAlarm indicates the supply
         voltage of the SFP/XFP in 1000s of Volts (V) that triggers a hi-alarm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 10 }

ddmTxBiasCurrent               OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | 0..10000)
	UNITS       "thousandth of a milli-Ampere"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTxBiasCurrent indicates the current Transmit
         Bias Current of the SFP/XFP in 1000s of milli-Amperes (mA).
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 11 }

ddmTxBiasCurrentLowWarning     OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | 0..10000)
	UNITS       "thousandth of a milli-Ampere"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTxBiasCurrentLowWarning indicates the Transmit
         Bias Current of the SFP/XFP in 1000s of milli-Amperes (mA) that triggers a
         low-warning.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 12 }

ddmTxBiasCurrentLowAlarm       OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | 0..10000)
	UNITS       "thousandth of a milli-Ampere"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTxBiasCurrentLowAlarm indicates the Transmit
         Bias Current of the SFP/XFP in 1000s of milli-Amperes (mA) that triggers a
         low-alarm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 13 }

ddmTxBiasCurrentHiWarning      OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | 0..10000)
	UNITS       "thousandth of a milli-Ampere"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTxBiasCurrentHiWarning indicates the Transmit
         Bias Current of the SFP/XFP in 1000s milli-Amperes (mA) that triggers a
         hi-warning.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 14 }

ddmTxBiasCurrentHiAlarm        OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | 0..10000)
	UNITS       "thousandth of a milli-Ampere"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTxBiasCurrentHiAlarm indicates the Transmit
         Bias Current of the SFP/XFP in 1000s milli-Amperes (mA) that triggers a
         hi-alarm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 15 }

ddmTxOutputPower               OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -40000..10000)
	UNITS       "thousandth of a dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTxOutputPower indicates the current Output
         Power of the SFP/XFP in 1000s of dBm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 16 }

ddmTxOutputPowerLowWarning     OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -40000..10000)
	UNITS       "thousandth of a dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTxOutputPowerLowWarning indicates the Output Power
         of the SFP/XFP in 1000s of dBm that triggers a low-warning.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 17 }

ddmTxOutputPowerLowAlarm       OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -40000..10000)
	UNITS       "thousandth of a dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTxOutputPowerLowAlarm indicates the Output Power
         of the SFP/XFP in 1000s of dBm that triggers a low-alarm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 18 }

ddmTxOutputPowerHiWarning      OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -40000..10000)
	UNITS       "thousandth of a dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTxOutputPowerHiWarning indicates the Output Power
         of the SFP/XFP in 1000s of dBm that triggers a hi-alarm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 19 }

ddmTxOutputPowerHiAlarm        OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -40000..10000)
	UNITS       "thousandth of a dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmTxOutputPowerHiAlarm indicates the Output Power
         of the SFP/XFP in 1000s of dBm that triggers a hi-alarm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 20 }

ddmRxOpticalPower              OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -40000..10000)
	UNITS       "thousandth of a dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmRxOpticalPower indicates the current Received
         Optical Power of the SFP/XFP in 1000s of dBm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 21 }

ddmRxOpticalPowerLowWarning    OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -40000..10000)
	UNITS       "thousandth of a dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmRxOpticalPowerLowWarning indicates the Received
         Optical Power of the SFP/XFP in 1000s of dBm that triggers a
         low-warning.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 22 }

ddmRxOpticalPowerLowAlarm      OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -40000..10000)
	UNITS       "thousandth of a dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmRxOpticalPowerLowAlarm indicates the Received
         Optical Power of the SFP/XFP in 1000s of dBm that triggers a
         low-alarm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 23 }

ddmRxOpticalPowerHiWarning     OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -40000..10000)
	UNITS       "thousandth of a dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmRxOpticalPowerHiWarning indicates the Received
         Optical Power of the SFP/XFP in 1000s of dBm that triggers a
         hi-warning.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 24 }

ddmRxOpticalPowerHiAlarm       OBJECT-TYPE
    SYNTAX      Integer32 (-200000 | -40000..10000)
	UNITS       "thousandth of a dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of ddmRxOpticalPowerHiAlarm indicates the Received
         Optical Power of the SFP/XFP in 1000s of dBm that triggers a
         hi-alarm.
		 A value of -200000 indicates this object is not applicable."
    ::= { ddmInfoEntry 25 }

--
alaEsmOldDb	OBJECT-TYPE
    SYNTAX      EsmDBType
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
	"This object specifies the module, either SFP+ daughter module or CX4 stacking
   	module, which was present before inserting a new module (either CX4 or SFP+)."
    ::= { esmDBChangeRebootReqdMIBObjects 1 }
alaEsmNewDb	OBJECT-TYPE
    SYNTAX      EsmDBType
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "This object specifies the module, either SFP+ daughter module or CX4 stacking
        module, which has been inserted."
    ::= { esmDBChangeRebootReqdMIBObjects 2 }
alaEsmModuleChangeString	OBJECT-TYPE
    SYNTAX      	SnmpAdminString (SIZE(1 .. 128))
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "This object specifies the string value describing reboot is required to activate the
	new module."
    ::= { esmDBChangeRebootReqdMIBObjects 3 }

alaOldDb	OBJECT-TYPE
    SYNTAX      AlaDBType
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
	"This object specifies the daughter module, which was present before inserting a new module."
    ::= { alaDBChangeMIBObjects 1 }

alaNewDb	OBJECT-TYPE
    SYNTAX      AlaDBType
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "This object specifies the daughter module, which has been inserted."
    ::= { alaDBChangeMIBObjects 2 }

alaModuleChangeString	OBJECT-TYPE
    SYNTAX     	SnmpAdminString (SIZE(1 .. 128))
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "This object specifies the string value describing 1) reboot is required to activate the
	new module. 2) New module can be used without reboot 3) No expansion module is present."
    ::= { alaDBChangeMIBObjects 3 }

-- Ethernet Driver Trap *********************

esmDrvTrapDropsLink  NOTIFICATION-TYPE
    OBJECTS    {
                  esmPortSlot,
		  esmPortIF,
                  ifInErrors,
                  ifOutErrors,
		  esmDrvTrapDrops
               }
    STATUS  current
    DESCRIPTION
           "When the Ethernet code drops the link because of
            excessive errors, a Trap is sent."
    ::= { cmmEsmDrvTraps 0 1 }

-- e2eStackTopoChangeTrap NOTIFICATION-TYPE
     -- OBJECTS    {
                   -- esmE2EFlowVlan
      --          }
     -- STATUS  current
     -- DESCRIPTION
       --     "Trap  Generated when  Stack Topology changes."
     -- ::= { cmmEsmDrvTraps 0 2 }

-- Dying Gasp Trap
alaDyingGaspTrap NOTIFICATION-TYPE
    OBJECTS     {
       	             alaDyingGaspSlot,
		     alaDyingGaspPowerSupplyType,
		     alaDyingGaspTime
                }
    STATUS      current
    DESCRIPTION
        "Dying Gasp trap."
    ::= { cmmEsmDrvTraps 0 3 }

-- Storm Control trap
    esmStormThresholdViolationStatus       NOTIFICATION-TYPE
     OBJECTS     {
                     ifIndex,
                     esmStormViolationThresholdNotificationType,
                     esmStormViolationThresholdTrafficType        

                 }
     STATUS      current
     DESCRIPTION
         "This object notifies management station if User-Port ports gets the ingress traffic inflow
                 above the configured value."

     ::= { cmmEsmDrvTraps 0 4} 
ddmTemperatureThresholdViolated NOTIFICATION-TYPE
	OBJECTS		{
					ifIndex,
					ddmNotificationType,
					ddmTemperature
				}
	STATUS		current
	DESCRIPTION
		"This object notifies management station if an SFP/XFP/SFP+ temperature has crossed any
		 threshold or reverted from previous threshold violation for a port represented by ifIndex.
		 It also provides the current realtime value of SFP/XFP/SFP+ temperature."
	::=	{ ddmNotifications 0 1 }
ddmVoltageThresholdViolated NOTIFICATION-TYPE
    OBJECTS     {
                    ifIndex,
                    ddmNotificationType,
                    ddmSupplyVoltage
                }
    STATUS      current
    DESCRIPTION
        "This object notifies management station if an SFP/XFP/SFP+ supply voltage has crossed any
         threshold or reverted from previous threshold violation for a port represented by ifIndex.
         It also provides the current realtime value of SFP/XFP/SFP+ supply voltage."
    ::= { ddmNotifications 0 2 }
ddmCurrentThresholdViolated NOTIFICATION-TYPE
    OBJECTS     {
                    ifIndex,
                    ddmNotificationType,
                    ddmTxBiasCurrent
                }
    STATUS      current
    DESCRIPTION
        "This object notifies management station if an SFP/XFP/SFP+ Tx bias current has crossed any
         threshold or reverted from previous threshold violation for a port represented by ifIndex.
         It also provides the current realtime value of SFP/XFP/SFP+ Tx bias current."
    ::= { ddmNotifications 0 3 }
ddmTxPowerThresholdViolated NOTIFICATION-TYPE
    OBJECTS     {
                    ifIndex,
                    ddmNotificationType,
                    ddmTxOutputPower
                }
    STATUS      current
    DESCRIPTION
        "This object notifies management station if an SFP/XFP/SFP+ Tx output power has crossed any
         threshold or reverted from previous threshold violation for a port represented by ifIndex.
         It also provides the current realtime value of SFP/XFP/SFP+ Tx output power."
    ::= { ddmNotifications 0 4 }
ddmRxPowerThresholdViolated NOTIFICATION-TYPE
    OBJECTS     {
                    ifIndex,
                    ddmNotificationType,
                    ddmRxOpticalPower
                }
    STATUS      current
    DESCRIPTION
        "This object notifies management station if an SFP/XFP/SFP+ Rx optical power has crossed any
         threshold or reverted from previous threshold violation for a port represented by ifIndex.
         It also provides the current realtime value of SFP/XFP/SFP+ Rx optical power."
    ::= { ddmNotifications 0 5 }


esmViolationRecoveryTimeout NOTIFICATION-TYPE
    OBJECTS     {
                    ifIndex,
                    esmViolationRecoveryNotificationType
                }
    STATUS      current
    DESCRIPTION
        "This object notifies management station if User-Port ports get re-enabled after esm violation recovery time"
    ::= { esmViolationNotifications 0 1 }

alaEsmKite2eDBChange	NOTIFICATION-TYPE
    OBJECTS     {
		    alaEsmOldDb,
		    alaEsmNewDb,
		    alaEsmModuleChangeString
		}
    STATUS      current
    DESCRIPTION
	"When SFP+ daughter module is inserted in place of CX4 stacking module or vice versa, then
	this notification is sent to Management Entity.
	Please note that if the old module and new module, defined by EsmDBType, are same, then this trap will not
	be sent."
    ::= { alcatelIND1PortNotifications 3 }

esmPortViolation NOTIFICATION-TYPE
    OBJECTS     {
                    ifIndex,
                    esmPortViolationValue
                }
    STATUS      current
    DESCRIPTION
        "This object notifies management station whenever an interface is shut down by a feature due to violation."
    ::= { alcatelIND1PortNotifications 4 }

alaDBChange	 NOTIFICATION-TYPE
    OBJECTS     {
		    alaOldDb,
		    alaNewDb,
		    alaModuleChangeString
		}
    STATUS      current
    DESCRIPTION
	"When there is a change in the expansion module presence, then this notification is sent to Management Entity.
	Please note that if the old module and new module, defined by AlaDBType, are same, then this trap will not
	be sent."
    ::= { alcatelIND1PortNotifications 5 }

-- TDR test Result Table
-- This table stores the result of TDR test comducted on the copper port(<slot,port>)
-- The object esmTdrPortTest can be used by the user to initiate the TDR test
-- All other objects are read only as length and states of the cable pairs can not be modified

-- conformance information

alcatelIND1PortMIBCompliances OBJECT IDENTIFIER ::=
                                          { alcatelIND1PortMIBConformance 1 }
alcatelIND1PortMIBGroups      OBJECT IDENTIFIER ::=
                                          { alcatelIND1PortMIBConformance 2 }

-- Link Monitoring Configuration Table
-- This table has configuration information Link Monitoring
alaLinkMonConfigTable OBJECT-TYPE
              SYNTAX SEQUENCE OF AlaLinkMonConfigEntry
              MAX-ACCESS not-accessible
              STATUS current
              DESCRIPTION
                  "A list of Link Monitoring Configuration Parameters"
              ::= { physicalPort 8 }
alaLinkMonConfigEntry OBJECT-TYPE
              SYNTAX AlaLinkMonConfigEntry
              MAX-ACCESS not-accessible
              STATUS current
              DESCRIPTION
                "A collection of Link Monitoring configurations kept for a particular
                 Ethernet interface."
              INDEX { ifIndex }
              ::= { alaLinkMonConfigTable 1 }
 
AlaLinkMonConfigEntry ::= SEQUENCE {
                 alaLinkMonStatus                       INTEGER,
                 alaLinkMonTimeWindow                   Integer32,
                 alaLinkMonLinkFlapThreshold            Integer32,
                 alaLinkMonLinkErrorThreshold           Integer32
          }
 
 
alaLinkMonStatus   OBJECT-TYPE
            SYNTAX INTEGER {
                                disable(0),
                                enable(1)
                           }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Allows the user to enable or disable Link Monitoring on the port."
            DEFVAL { disable }
          ::= { alaLinkMonConfigEntry 1}
 
alaLinkMonTimeWindow   OBJECT-TYPE
            SYNTAX Integer32 (0..3600)
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Indicates the number of seconds the Link will be monitored for a port."
            DEFVAL { 300 }
          ::= { alaLinkMonConfigEntry 2}
 
alaLinkMonLinkFlapThreshold   OBJECT-TYPE
            SYNTAX Integer32 (2..10)
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Indicaes the number of link flaps allowed for the specified port
                  during the time window before the port is shutdown."
            DEFVAL { 5 }
          ::= { alaLinkMonConfigEntry 3}
alaLinkMonLinkErrorThreshold   OBJECT-TYPE
            SYNTAX Integer32 (1..100)
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                 "Indicates the number of link errors allowed on Rx for the specified port
                  during the time window before the port is shutdown. The errors are the MAC errors
                  that include CRC, lost frames, error frames, alignment frames."
            DEFVAL { 5 }
          ::= { alaLinkMonConfigEntry 4 }
 
 
-- Link Monitoring Stats Table
-- It has all the statistics information for Link Monitoring
 
alaLinkMonStatsTable OBJECT-TYPE
              SYNTAX SEQUENCE OF AlaLinkMonStatsEntry
              MAX-ACCESS not-accessible
              STATUS current
              DESCRIPTION
                  "A list of Link Monitoring Statistics"
              ::= { physicalPort 9 }
alaLinkMonStatsEntry OBJECT-TYPE
              SYNTAX AlaLinkMonStatsEntry
              MAX-ACCESS not-accessible
              STATUS current
              DESCRIPTION
                  "A collection of Link Monitoring statistics for a particular
                  Ethernet interface."
              INDEX { ifIndex }
              ::= { alaLinkMonStatsTable 1 }
 
AlaLinkMonStatsEntry ::= SEQUENCE {
                alaLinkMonStatsClearStats               INTEGER,
                alaLinkMonStatsPortState                INTEGER,
                alaLinkMonStatsCurrentLinkFlaps         Counter64,
                alaLinkMonStatsCurrentErrorFrames       Counter64,
                alaLinkMonStatsCurrentCRCErrors         Counter64,
                alaLinkMonStatsCurrentLostFrames        Counter64,
                alaLinkMonStatsCurrentAlignErrors       Counter64,
                alaLinkMonStatsCurrentLinkErrors        Counter64,
                alaLinkMonStatsTotalLinkFlaps           Counter64,
                alaLinkMonStatsTotalLinkErrors          Counter64
          }
alaLinkMonStatsClearStats   OBJECT-TYPE
            SYNTAX INTEGER {
                                default(0),
                                reset(1)
                           }
 
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
               "Used to Clear all Statistics counters.
               The value reset (1) indicates that Link Monitoring shuold all statistic
               counters related to the particular port.
               By default, this object contains zero value."
            DEFVAL {default}
          ::= { alaLinkMonStatsEntry 1 }
 
alaLinkMonStatsPortState   OBJECT-TYPE
            SYNTAX INTEGER {
                                up(1),
                                down(2),
                                shutdown(3)
                           }
            MAX-ACCESS  read-only
            STATUS  current
            DESCRIPTION
                 "Indicates the status of the port.
                  up(1) means the port is physically up, down(2) means the port is physically down,
                  shutdown(3) means the interface is shutdown because of excessive link flaps or link errors."
 
          ::= { alaLinkMonStatsEntry 2 }
 
alaLinkMonStatsCurrentLinkFlaps   OBJECT-TYPE
            SYNTAX Counter64
            MAX-ACCESS  read-only
            STATUS  current
            DESCRIPTION
                 "Indicates the number of Link flaps in the current time window."
 
          ::= { alaLinkMonStatsEntry 3 }
 
 
alaLinkMonStatsCurrentErrorFrames   OBJECT-TYPE
            SYNTAX Counter64
            MAX-ACCESS  read-only
            STATUS  current
            DESCRIPTION
                 "Indicates the number of error frames in the current time window."
 
          ::= { alaLinkMonStatsEntry 4 }
 
 
alaLinkMonStatsCurrentCRCErrors   OBJECT-TYPE
            SYNTAX Counter64
            MAX-ACCESS  read-only
            STATUS  current
            DESCRIPTION
                 "Indicates the number of CRC errors in the current time window."
 
          ::= { alaLinkMonStatsEntry 5 }
 
alaLinkMonStatsCurrentLostFrames   OBJECT-TYPE
            SYNTAX Counter64
            MAX-ACCESS  read-only
            STATUS  current
            DESCRIPTION
                 "Indicates the number of Rx Lost frames in the current time window."
 
          ::= { alaLinkMonStatsEntry 6 }
 
 
alaLinkMonStatsCurrentAlignErrors   OBJECT-TYPE
            SYNTAX Counter64
            MAX-ACCESS  read-only
            STATUS  current
            DESCRIPTION
                 "Indicates the number of Rx alignment frames in the current time window."
 
          ::= { alaLinkMonStatsEntry 7 }
 
 
alaLinkMonStatsCurrentLinkErrors   OBJECT-TYPE
            SYNTAX Counter64
            MAX-ACCESS  read-only
            STATUS  current
            DESCRIPTION
                 "Indicates the sum of all the MAC Errors within the current time window.
                  i.e., the sum of alaLinkMonStatsCurrentErrorFrames, alaLinkMonStatsCurrentCRCErrors,
                  alaLinkMonCurrentLosFrames, alaLinkMonStatsCurrentAlignErrors."
 
          ::= { alaLinkMonStatsEntry 8 }
alaLinkMonStatsTotalLinkFlaps   OBJECT-TYPE
            SYNTAX Counter64
            MAX-ACCESS  read-only
            STATUS  current
            DESCRIPTION
                 "Indicates the total number of link flaps across all the time windows."
 
          ::= { alaLinkMonStatsEntry 9 }
 
alaLinkMonStatsTotalLinkErrors   OBJECT-TYPE
            SYNTAX Counter64
            MAX-ACCESS  read-only
            STATUS  current
            DESCRIPTION
                 "Indicates the total number of link errors across all the time windows."
 
          ::= { alaLinkMonStatsEntry 10 }
 
 
-- Link Fault Propagation (LFP) Configuration Table
-- It has all the Configuration information for LFP
 
alaLFPGroupTable OBJECT-TYPE
    SYNTAX SEQUENCE OF AlaLFPGroupEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A list of Link Fault Propagation Grooups and their status"
    ::= {physicalPort 10 }
 
alaLFPGroupEntry OBJECT-TYPE
    SYNTAX      AlaLFPGroupEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The list of Link Fault Propagation group id and status for each group"
    INDEX { alaLFPGroupId  }
    ::= { alaLFPGroupTable 1 }
 
AlaLFPGroupEntry ::= SEQUENCE
    {
            alaLFPGroupId               Integer32,
            alaLFPGroupAdminStatus      INTEGER,
            alaLFPGroupOperStatus       INTEGER,
            alaLFPGroupWaitToShutdown   Integer32,
            alaLFPGroupRowStatus        RowStatus
    }
 
alaLFPGroupId   OBJECT-TYPE
    SYNTAX Integer32 (1 .. 8 )
    MAX-ACCESS  accessible-for-notify
    STATUS  current
    DESCRIPTION
        "Indicates the unique group id for Link Fault Propagation (LFP)."
 
    ::= { alaLFPGroupEntry 1 }
alaLFPGroupAdminStatus   OBJECT-TYPE
    SYNTAX INTEGER {
                       disable(0),
                       enable(1)
                   }
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
        "Indicates the admin status of the group. disable(0) means link fault propagation,
         is disbaled. enable(1) means link fault propagation is enabled"
    DEFVAL { disable }
    ::= { alaLFPGroupEntry 2 }
 
alaLFPGroupOperStatus   OBJECT-TYPE
    SYNTAX INTEGER {
                       down(0),
                       up(1)
                   }
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "Indicates the operational status of the group. down(0) means all the source ports are down,
         up(1) means atleast one source port in the group is up."
    ::= { alaLFPGroupEntry 3 }
alaLFPGroupWaitToShutdown   OBJECT-TYPE
    SYNTAX Integer32 (0 .. 300)
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
        "0 - Disable wait to shutdown timer
         Range 5 - 300, in multiples of 5. After expiry of this timer all destination ports will be shutdown"
    DEFVAL { 0 }
    ::= { alaLFPGroupEntry 4 }
 
alaLFPGroupRowStatus   OBJECT-TYPE
    SYNTAX RowStatus
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
        "Row Status for initiating a MIB retrieval request."
    ::= { alaLFPGroupEntry 5 }
 
alaLFPConfigTable OBJECT-TYPE
    SYNTAX SEQUENCE OF AlaLFPConfigEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A list of Link Fault Propagation port and port type of each LFP group"
    ::= {physicalPort 11 }
alaLFPConfigEntry OBJECT-TYPE
    SYNTAX      AlaLFPConfigEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A list of Link Fault Propagation port and port type of each LFP group"
    INDEX { alaLFPGroupId, alaLFPConfigPort }
    ::= { alaLFPConfigTable 1 }
 
AlaLFPConfigEntry ::= SEQUENCE
    {
        alaLFPConfigPort       InterfaceIndex,
        alaLFPConfigPortType   INTEGER,
        alaLFPConfigRowStatus  RowStatus
    }
 
alaLFPConfigPort   OBJECT-TYPE
    SYNTAX InterfaceIndex
    MAX-ACCESS  accessible-for-notify
    STATUS  current
    DESCRIPTION
        "Indicates ifindex of source/destination port for a LFP Group."
    ::= { alaLFPConfigEntry 1 }
alaLFPConfigPortType   OBJECT-TYPE
    SYNTAX INTEGER {
                       destination (1),
                       source (2)
                   }
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
        "Indicates the type of port, (1) means the port is destination port and
         (2) means the port is a source port for a LFP Group."
    ::= { alaLFPConfigEntry 2 }
 
alaLFPConfigRowStatus   OBJECT-TYPE
    SYNTAX RowStatus
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
        "Row Status for initiating a MIB retrieval request."
    ::= { alaLFPConfigEntry 3 }

ptpConfig OBJECT-TYPE
	SYNTAX		INTEGER {
					enable(1),
					disable(2)
				}
	MAX-ACCESS	read-write
	STATUS		current
	DESCRIPTION
		"This object enables/disables PTP software feature in the system."
	DEFVAL		{ disable }
	::= { ptpConfiguration 1 }

esmPtpStatsTable OBJECT-TYPE
        SYNTAX          SEQUENCE OF EsmPtpStatsEntry
        MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION
                "The table lists the Statistics params of PTP."
        ::= {physicalPort 13 }

esmPtpStatsEntry OBJECT-TYPE
        SYNTAX          EsmPtpStatsEntry
        MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION
                "An entry corresponding to each port."
        INDEX           { ifIndex }
        ::= { esmPtpStatsTable 1 }

EsmPtpStatsEntry ::= SEQUENCE {
                                esmPtpStatsIngPtpv2    		Unsigned32,
                                esmPtpStatsIngPtpv1   		Unsigned32,
                                esmPtpStatsIngPtpDrop   	Unsigned32,
                                esmPtpStatsIngPtpPigBag   	Unsigned32,
                                esmPtpStatsEgrPtpv2  		Unsigned32,
                                esmPtpStatsEgrPtpv1   		Unsigned32,
                                esmPtpStatsEgrPtpDrop		Unsigned32,	
                                esmPtpStatsEgrPtpUpdateRes	Unsigned32	
                             }

esmPtpStatsIngPtpv2    OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The number of PTP V2 packets ingress in to the port"
        ::= { esmPtpStatsEntry 1 }

esmPtpStatsIngPtpv1    OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The number of PTP V1 packets ingress in to the port"
        ::= { esmPtpStatsEntry 2 }

esmPtpStatsIngPtpDrop   OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The number of PTP packets dropped at ingress by the port"
        ::= { esmPtpStatsEntry 3 }

esmPtpStatsIngPtpPigBag OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The number of PTP Piggy Bag added to ingress packets in the port"
        ::= { esmPtpStatsEntry 4 }

esmPtpStatsEgrPtpv2    OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The number of PTP V2 packets egress from the port"
        ::= { esmPtpStatsEntry 5 }

esmPtpStatsEgrPtpv1    OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The number of PTP V1 packets egress from the port"
        ::= { esmPtpStatsEntry 6 }

esmPtpStatsEgrPtpDrop   OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "The number of PTP packets dropped at egress by the port"
        ::= { esmPtpStatsEntry 7 }

esmPtpStatsEgrPtpUpdateRes OBJECT-TYPE
        SYNTAX             Unsigned32
        MAX-ACCESS         read-only
        STATUS             current
        DESCRIPTION
                "The number of PTP residence time updated packets in the port"
        ::= { esmPtpStatsEntry 8 }

-- ESM Stack port information table
        esmStackPortTable  OBJECT-TYPE
            SYNTAX  SEQUENCE OF EsmStackPortConfEntry
            MAX-ACCESS  not-accessible
            STATUS  current
            DESCRIPTION
                "A list of Stacking Link statistics"
            ::= { physicalPort 14 }

        esmStackPortConfEntry  OBJECT-TYPE
            SYNTAX  EsmStackPortConfEntry
            MAX-ACCESS  not-accessible
            STATUS  current
            DESCRIPTION
                "A collection of statistics kept for a Stacking Link."
            INDEX { esmStackPortIfIndex }
            ::= { esmStackPortTable 1 }

EsmStackPortConfEntry ::= SEQUENCE {
                    esmStackPortIfIndex                 InterfaceIndex,
                    esmStackPortSlotNum                 Integer32,
                    esmStackPortInOctets                Counter64,
                    esmStackPortOutOctets               Counter64,
                    esmStackPortInUcastPkts             Counter64,
                    esmStackPortOutUcastPkts            Counter64,   
                    esmStackPortInMulticastPkts         Counter64,                   
                    esmStackPortOutMulticastPkts        Counter64,       
                    esmStackPortInBroadcastPkts         Counter64,       
                    esmStackPortOutBroadcastPkts        Counter64,                 
                    esmStackPortInPauseFrames           Counter64,
                    esmStackPortOutPauseFrames          Counter64,
                    esmStackPortStatsAlignmentErrors    Counter64,                   
                    esmStackPortStatsFCSErrors          Counter64,
                    esmStackPortInErrors                Counter64, 
                    esmStackPortOutErrors               Counter64,  
                    esmStackPortInDiscards              Counter64, 
                    esmStackPortOutDiscards             Counter64, 
		      esmStackPortTxCollisions            Counter64, 
                    esmStackPortRxUndersizePkts         Counter64,
		      esmStackPortTxUndersizePkts         Counter64,
                    esmStackPortRxOversizePkts          Counter64,
                    esmStackPortTxOversizePkts          Counter64,
		      esmStackPortAutoSpeed               INTEGER,
		   esmStackPortClearStats              INTEGER
        }           

esmStackPortIfIndex OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "A unique value, greater than zero, for each stack port interface."
    ::= { esmStackPortConfEntry 1 }

esmStackPortSlotNum  OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
        "The on-board slot number of stack ports."
    ::= { esmStackPortConfEntry 2 }
	
esmStackPortInOctets OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "The total number of octets received on the stacking interface,
            including framing characters."
    ::= { esmStackPortConfEntry 3  }
	
esmStackPortOutOctets OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "The total number of octets transmitted out of the
            stacking interface, including framing characters."
    ::= { esmStackPortConfEntry 4 }
			  
esmStackPortInUcastPkts  OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "The number of packets, delivered by this sub-layer to a
            higher (sub-)layer, which were not addressed to a multicast
            or broadcast address at this sub-layer."
    ::= { esmStackPortConfEntry 5 }
	
esmStackPortOutUcastPkts OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "The total number of packets that higher-level protocols
            requested be transmitted, and which were not addressed to a
            multicast or broadcast address at this sub-layer, including
            those that were discarded or not sent."
    ::= { esmStackPortConfEntry 6 }
	
esmStackPortInMulticastPkts OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "The number of packets, delivered by this sub-layer to a
            higher (sub-)layer, which were addressed to a multicast
            address at this sub-layer.  For a MAC layer protocol, this
            includes both Group and Functional addresses."
    ::= { esmStackPortConfEntry 7 }
	
esmStackPortOutMulticastPkts OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "The total number of packets that higher-level protocols
            requested be transmitted, and which were addressed to a
            multicast address at this sub-layer, including those that
            were discarded or not sent.  For a MAC layer protocol, this
            includes both Group and Functional addresses."
    ::= { esmStackPortConfEntry 8 }
	
esmStackPortInBroadcastPkts OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "The number of packets, delivered by this sub-layer to a
            higher (sub-)layer, which were addressed to a broadcast
            address at this sub-layer."
    ::= { esmStackPortConfEntry 9 }
	
esmStackPortOutBroadcastPkts OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "The total number of packets that higher-level protocols
            requested be transmitted, and which were addressed to a
            broadcast address at this sub-layer, including those that
            were discarded or not sent."
    ::= { esmStackPortConfEntry 10 }
	
esmStackPortInPauseFrames OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "A count of MAC Control frames received on stacking 
                 interface with an opcode indicating the PAUSE operation."
    ::= { esmStackPortConfEntry 11 }
		   
esmStackPortOutPauseFrames OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "A count of MAC Control frames transmitted on
                stacking interface with an opcode indicating the
                PAUSE operation."
    ::= { esmStackPortConfEntry 12 }
		   
esmStackPortStatsAlignmentErrors OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "A count of frames received on the stacking
                 interface that are not an integral number of
                octets in length and do not pass the FCS check.

                The count represented by an instance of this
                object is incremented when the alignmentError
                status is returned by the MAC service to the
                LLC (or other MAC user). Received frames for
                which multiple error conditions obtain are,
                according to the conventions of IEEE 802.3
                Layer Management, counted exclusively according
                to the error status presented to the LLC.

                This counter does not increment for 8-bit wide
                group encoding schemes."
    ::= { esmStackPortConfEntry 13 }
	
esmStackPortStatsFCSErrors OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "A count of frames received on the stacking
                interface that are an integral number of octets
                in length but do not pass the FCS check.  This
                count does not include frames received with
                frame-too-long or frame-too-short error.

                The count represented by an instance of this
                object is incremented when the frameCheckError
                status is returned by the MAC service to the
                LLC (or other MAC user). Received frames for
                which multiple error conditions obtain are,
                according to the conventions of IEEE 802.3
                Layer Management, counted exclusively according
                to the error status presented to the LLC.

                Note:  Coding errors detected by the physical
                layer for speeds above 10 Mb/s will cause the
                frame to fail the FCS check."
    ::= { esmStackPortConfEntry 14 }
	
esmStackPortInErrors OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
             "For a stacking interface, the number of inbound packets that 
		contained errors preventing them from being deliverable 
		to a higher-layer protocol.  For character-oriented or 
		fixed-length interfaces, the number of inbound 
		transmission units that contained errors preventing them   
              from being deliverable to a higher-layer protocol."  
    ::= { esmStackPortConfEntry 15 }
	
esmStackPortOutErrors OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
             "For a stacking interface, the number of outbound packets 
	      that could not be transmitted because of errors.   
             For character-oriented or fixed-length interfaces, the   
             number of outbound transmission units that could not be   
             transmitted because of errors." 
    ::= { esmStackPortConfEntry 16 }
	
esmStackPortInDiscards OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "The number of inbound packets which were chosen to be
            discarded even though no errors had been detected to prevent
            their being deliverable to a higher-layer protocol.  One
            possible reason for discarding such a packet could be to
            free up buffer space."
    ::= { esmStackPortConfEntry 17 }
	
esmStackPortOutDiscards OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "The number of outbound packets which were chosen to be
            discarded even though no errors had been detected to prevent
            their being transmitted.  One possible reason for discarding
            such a packet could be to free up buffer space."
    ::= { esmStackPortConfEntry 18 }
	
esmStackPortTxCollisions OBJECT-TYPE
    SYNTAX Counter64
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
        "The estimate of the total number of collisions."
	::= { esmStackPortConfEntry 19 }
	
esmStackPortRxUndersizePkts OBJECT-TYPE
    SYNTAX Counter64
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
        "The total number of packets received that were
        less than 64 octets long (excluding framing bits,
        but including FCS octets) and were otherwise well
        formed."
    ::= { esmStackPortConfEntry 20 }
	
esmStackPortTxUndersizePkts OBJECT-TYPE
    SYNTAX Counter64
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
        "The total number of packets transmitted that were
        less than 64 octets long (excluding framing bits,
        but including FCS octets) and were otherwise well
        formed."
    ::= { esmStackPortConfEntry 21 }
	
esmStackPortRxOversizePkts OBJECT-TYPE
    SYNTAX Counter64
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
        "The total number of packets received that were
        longer than 1518 octets long (excluding framing bits,
        but including FCS octets) and were otherwise well
        formed."
    ::= { esmStackPortConfEntry 22 }
	
esmStackPortTxOversizePkts OBJECT-TYPE
    SYNTAX Counter64
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
        "The total number of packets transmitted that were
        longer than 1518 octets long (excluding framing bits,
        but including FCS octets) and were otherwise well
        formed."
    ::= { esmStackPortConfEntry 23 }
	
esmStackPortAutoSpeed OBJECT-TYPE
    SYNTAX INTEGER{
       speed100(1),
       speed10(2),
       speedAuto(3),
       unknown(4),
       speed1000(5),
       speed10000(6)
    } 
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
        "The automatically detected port line speed
         of the stack port."
    ::= { esmStackPortConfEntry 24 }
	
esmStackPortClearStats OBJECT-TYPE   
    SYNTAX INTEGER   
      {        default(0),   
                reset(1)
      }
      MAX-ACCESS read-write
      STATUS current   
     DESCRIPTION   
          "Used to Clear all Stack Port Statistics counters.
                     By default, this object contains zero value."   
      ::= { esmStackPortConfEntry 25 }

		
-- compliance statements

esmConfPortCompliance MODULE-COMPLIANCE
    STATUS  current
    DESCRIPTION
            "The compliance statement for the configuration of Ethernet
            ports."
    MODULE  -- this module
        MANDATORY-GROUPS { 
			   esmConfMIBGroup, 
			   esmDetectedConfMIBGroup,
                           esmPortModeMIBGroup,
			   ddmInfoGroup,
			   ddmConfigGroup,
                           ddmNotificationsGroup,
			   violationRecoveryGroup,
			   violationNotificationsGroup,
			   alaDyingGaspNotificationGroup,
			   esmDrvDyingGaspNotificationGroup,
			   alaPortViolationRecoveryMIBGroup,
			   esmConfTrapGroup,
			   esmTdrGroup,
                           alaEsmDBObjGroup,
                           alsEsmDBChangeNotificationGroup,
                           alaLinkMonConfigMIBGroup,
                           alaLFPGroupMIBGroup,
                           alaLFPConfigMIBGroup,
                           alcether10GigGroup,
                           esmHybridConfGroup,
                           esmStormThresholdViolationGroup,
                        ptpConfigGroup,
                        esmStackPortConfMIBGroup 
			 }

    ::= { alcatelIND1PortMIBCompliances 1 }

alcEtherStatsCompliance MODULE-COMPLIANCE
    STATUS  current
    DESCRIPTION
            "The compliance statement for the Statistics of the Ethernet
            ports."
    MODULE  -- this module
        MANDATORY-GROUPS { alcEtherStatsMIBGroup ,alaLinkMonStatsMIBGroup}

    ::= { alcatelIND1PortMIBCompliances 2 }

esmSlotInfoCompliance MODULE-COMPLIANCE
    STATUS  current
    DESCRIPTION
            "The compliance statement for the esm per slot information."
    MODULE  -- this module
        MANDATORY-GROUPS { esmSlotInfoGroup }

    ::= { alcatelIND1PortMIBCompliances 3 }

-- units of conformance

esmConfMIBGroup OBJECT-GROUP
    OBJECTS { esmPortSlot, esmPortIF,esmPortCfgSpeed,
              esmPortCfgDuplexMode, esmPortCfgIFG,
              esmPortPauseSlotTime, esmPortMaxFloodRate,
	      esmPortFloodMcastEnable, esmPortCfgMaxFrameSize, esmPortCfgAutoNegotiation,
       	      esmPortCfgCrossover, esmPortCfgFlow, esmPortOperationalHybridType, esmPortFloodUnknownUcastEnable,
	          esmPortMaxUnknownUcastFloodRate,esmPortMaxMcastFloodRate, 
              esmPortViolationClearAll, esmPortFloodBcastEnable, esmPortMaxFloodRateLimit,
              esmPortMaxUnknownUcastFloodRateLimit,esmPortMaxMcastFloodRateLimit,esmPortMinMcastFloodRateLimit,
		esmPortFloodThresholdAction, esmPortMcastThresholdAction, esmPortFlood, esmPortMCastStorm,
              esmPortViolationClearAll, esmPortCfgSFPType, esmPortWaitToRestoreTimer,esmPortCfgEeeStatus,esmPortCfgEeeAutoNegState,esmPortCfgEeeCapability,
              esmPortCfgLongEnable ,
              esmPortCfgMMUDynamicCellSetLimit, esmPortCfgMMULowWaterMarkCellSetLimit

            }
    STATUS  current
    DESCRIPTION
            "A collection of objects to support the management of global
            configuration parameters of the Ethernet ports."
    ::= { alcatelIND1PortMIBGroups 1 }

esmDetectedConfMIBGroup OBJECT-GROUP
    OBJECTS { esmPortAutoSpeed, esmPortAutoDuplexMode
            }
    STATUS  current
    DESCRIPTION
            "A collection of objects to support the Detected
            configuration parameters of the Ethernet ports."
    ::= { alcatelIND1PortMIBGroups 2 }

alcEtherStatsMIBGroup OBJECT-GROUP
    OBJECTS { alcetherClearStats, alcetherLastClearStats,
	      alcetherStatsCRCAlignErrors, alcetherStatsRxUndersizePkts,
              alcetherStatsTxUndersizePkts, alcetherStatsTxOversizePkts,
	      alcetherStatsRxJabbers, alcetherStatsRxCollisions,
	      alcetherStatsTxCollisions, alcetherStatsPkts64Octets,
              alcetherStatsPkts65to127Octets, alcetherStatsPkts128to255Octets,
              alcetherStatsPkts256to511Octets,
	      alcetherStatsPkts512to1023Octets,
	      alcetherStatsPkts1024to1518Octets,
              gigaEtherStatsPkts1519to4095Octets,
	      gigaEtherStatsPkts4096to9215Octets,
		alcetherStatsPkts1519to2047Octets,
		alcetherStatsPkts2048to4095Octets,
		alcetherStatsPkts4096Octets,
		alcetherStatsRxGiantPkts,
		alcetherStatsRxDribbleNibblePkts,
		alcetherStatsRxLongEventPkts,
		alcetherStatsRxVlanTagPkts,
		alcetherStatsRxControlPkts,
		alcetherStatsRxLenChkErrPkts,
		alcetherStatsRxCodeErrPkts,
		alcetherStatsRxDvEventPkts,
		alcetherStatsRxPrevPktDropped,
		alcetherStatsTx64Octets,
		alcetherStatsTx65to127Octets,
		alcetherStatsTx128to255Octets,
		alcetherStatsTx256to511Octets,
		alcetherStatsTx512to1023Octets,
		alcetherStatsTx1024to1518Octets,
		alcetherStatsTx1519to2047Octets,
		alcetherStatsTx2048to4095Octets,
		alcetherStatsTx4096Octets,
		alcetherStatsTxRetryCount,
		alcetherStatsTxVlanTagPkts,
		alcetherStatsTxControlPkts,
		alcetherStatsTxLatePkts,
		alcetherStatsTxTotalBytesOnWire,
		alcetherStatsTxLenChkErrPkts,
		alcetherStatsTxExcDeferPkts

            }
    STATUS  current
    DESCRIPTION
            "A collection of objects to provide all the statistics related
             to the Ethernet and GigaEthernert ports."
    ::= { alcatelIND1PortMIBGroups 3 }

alcPortNotificationGroup NOTIFICATION-GROUP
    NOTIFICATIONS {
	esmDrvTrapDropsLink
	-- e2eStackTopoChangeTrap
	}
    STATUS current
    DESCRIPTION
 	    "The Port MIB Notification Group."
    ::= { alcatelIND1PortMIBGroups 4 }


esmPortModeMIBGroup OBJECT-GROUP
    OBJECTS { esmPortRunningMode,
              esmPortSavedMode
            }
    STATUS  current
    DESCRIPTION
            "A collection of objects to support the management of global
            configuration parameters of the stacking ports."
    ::= { alcatelIND1PortMIBGroups 5 }

esmDrvDyingGaspNotificationGroup NOTIFICATION-GROUP
        NOTIFICATIONS   {
                               alaDyingGaspTrap 
                        }
        STATUS  current
        DESCRIPTION
                        "A collection of notifications used to indicate dying gasp trap."
        ::= { alcatelIND1PortMIBGroups 25 }


     ddmInfoGroup        OBJECT-GROUP 
         OBJECTS        { 
                         ddmTemperature, 
                         ddmTempLowWarning, 
                         ddmTempLowAlarm, 
                         ddmTempHiWarning, 
                         ddmTempHiAlarm, 
                         ddmSupplyVoltage, 
                         ddmSupplyVoltageLowWarning, 
                         ddmSupplyVoltageLowAlarm, 
                         ddmSupplyVoltageHiWarning, 
                         ddmSupplyVoltageHiAlarm, 
                         ddmTxBiasCurrent, 
                         ddmTxBiasCurrentLowWarning, 
                         ddmTxBiasCurrentLowAlarm, 
                         ddmTxBiasCurrentHiWarning, 
                         ddmTxBiasCurrentHiAlarm, 
                         ddmTxOutputPower, 
                         ddmTxOutputPowerLowWarning, 
                         ddmTxOutputPowerLowAlarm, 
                         ddmTxOutputPowerHiWarning, 
                         ddmTxOutputPowerHiAlarm, 
                         ddmRxOpticalPower, 
                         ddmRxOpticalPowerLowWarning, 
                         ddmRxOpticalPowerLowAlarm, 
                         ddmRxOpticalPowerHiWarning, 
                         ddmRxOpticalPowerHiAlarm 
                         } 
         STATUS        current 
         DESCRIPTION 
                         "A collection of objects to provide digital diagnostics information 
                          related to SFPs, XFPs, and SFP+s." 
         ::=        { alcatelIND1PortMIBGroups 6 } 


    ddmConfigGroup        OBJECT-GROUP 
         OBJECTS { 
                                 ddmConfig,
                                 ddmTrapConfig,
                                 ddmNotificationType 
                         } 
         STATUS        current 
         DESCRIPTION 
                         "A collection of objects to allow configuration of DDM and DDM traps." 
         ::=        { alcatelIND1PortMIBGroups 7 }

	ddmNotificationsGroup	NOTIFICATION-GROUP
	NOTIFICATIONS	{
						ddmTemperatureThresholdViolated,
						ddmVoltageThresholdViolated,
						ddmCurrentThresholdViolated,
						ddmTxPowerThresholdViolated,
						ddmRxPowerThresholdViolated
					}
	STATUS	current
	DESCRIPTION
			"A collection of notifications used to indicate DDM threshold violations."
	::= { alcatelIND1PortMIBGroups 8 }
	violationRecoveryGroup	OBJECT-GROUP
	OBJECTS {
				esmViolationRecoveryTrap,
				esmViolationRecoveryTime,
				esmViolationRecoveryNotificationType,
				esmViolationRecoveryMaximum
			}
	STATUS	current
	DESCRIPTION
			"A collection of objects to allow configuration of violationRecovery."
	::=	{ alcatelIND1PortMIBGroups 9 }
	violationNotificationsGroup NOTIFICATION-GROUP
	NOTIFICATIONS	{
						esmViolationRecoveryTimeout
			}
	STATUS	current
	DESCRIPTION
			"A collection of notifications used to indicate esm violation recovery timeout."
	::= { alcatelIND1PortMIBGroups 10 }
	alaDyingGaspNotificationGroup NOTIFICATION-GROUP
        NOTIFICATIONS   {
                               alaDyingGaspTrap
                        }
        STATUS  current
        DESCRIPTION
                        "A collection of notifications used to indicate dying gasp trap."
        ::= { alcatelIND1PortMIBGroups 11 }

        esmTdrGroup     OBJECT-GROUP
        OBJECTS {
                                  esmTdrPortCableState,
                                esmTdrPortValidPairs,
                                esmTdrPortPair1State,
                                esmTdrPortPair1Length,
                                esmTdrPortPair2State,
                                esmTdrPortPair2Length,
                                esmTdrPortPair3State,
                                esmTdrPortPair3Length,
                                esmTdrPortPair4State,
                                esmTdrPortPair4Length,
                                esmTdrPortFuzzLength,
                                esmTdrPortTest,
                                esmTdrClearStats,
                                esmTdrResult,
                                esmTdrPortExtSwapTypeChannel1,
                                esmTdrPortExtSwapTypeChannel2,     
                                esmTdrPortExtPolaritySwapPair1, 
                                esmTdrPortExtPolaritySwapPair2, 
                                esmTdrPortExtPolaritySwapPair3, 
                                esmTdrPortExtPolaritySwapPair4, 
                                esmTdrPortExtSkewPair1, 
                                esmTdrPortExtSkewPair2, 
                                esmTdrPortExtSkewPair3, 
                                esmTdrPortExtSkewPair4, 
                                esmTdrPortExtAccurateCableLenPair1,     
                                esmTdrPortExtAccurateCableLenPair2,     
                                esmTdrPortExtAccurateCableLenPair3,     
                                esmTdrPortExtAccurateCableLenPair4,     
                                esmTdrPortExtDownshiftStatus,   
                                esmTdrExtResult, 
                                esmTdrCableLen, 
                                esmTdrPhyType   
                        }
        STATUS  current
        DESCRIPTION
                        "A collection of objects to provide TDR information"
        ::=     { alcatelIND1PortMIBGroups 12 }

   alaEsmDBObjGroup	OBJECT-GROUP
	OBJECTS	{
			alaEsmOldDb,
			alaEsmNewDb,
			alaEsmModuleChangeString
		}
	STATUS	current
	DESCRIPTION
                        "A collection of objects to provide DB change trap information."
	::= { alcatelIND1PortMIBGroups 13 }
	
        alsEsmDBChangeNotificationGroup NOTIFICATION-GROUP
        NOTIFICATIONS   {
                                alaEsmKite2eDBChange
                     	}
        STATUS  current
        DESCRIPTION
                        "A collection of notifications used to indicate DB change trap."
        ::= { alcatelIND1PortMIBGroups 14 }

   alaLinkMonConfigMIBGroup OBJECT-GROUP
    	OBJECTS {			
			alaLinkMonStatus,
			alaLinkMonTimeWindow,
			alaLinkMonLinkFlapThreshold,
			alaLinkMonLinkErrorThreshold
		}
    	STATUS  current
    	DESCRIPTION
            "A collection of objects to support the Link Monitoring Configurations on the ports."
    	::= { alcatelIND1PortMIBGroups 15 }
	alaLinkMonStatsMIBGroup OBJECT-GROUP
    	OBJECTS {
			alaLinkMonStatsClearStats,
			alaLinkMonStatsPortState,
			alaLinkMonStatsCurrentLinkFlaps,
			alaLinkMonStatsCurrentErrorFrames,
			alaLinkMonStatsCurrentCRCErrors,
			alaLinkMonStatsCurrentLostFrames,
			alaLinkMonStatsCurrentAlignErrors,
			alaLinkMonStatsCurrentLinkErrors,
			alaLinkMonStatsTotalLinkFlaps,
			alaLinkMonStatsTotalLinkErrors
		}
    	STATUS  current
    	DESCRIPTION
            "A collection of objects to provide all the statistics related
             to the Link Monitoring on the ports."
    	::= { alcatelIND1PortMIBGroups 16 }
	alaLFPGroupMIBGroup OBJECT-GROUP
    	OBJECTS {
			alaLFPGroupId,
			alaLFPGroupAdminStatus,
			alaLFPGroupOperStatus,
			alaLFPGroupWaitToShutdown,
			alaLFPGroupRowStatus
		}
    	STATUS  current
    	DESCRIPTION
            "A collection of objects to configure Link Fault Propagation Group,
             Wait to shutdown timer and admin staus of group."
    	::= { alcatelIND1PortMIBGroups 17 }
	alaLFPConfigMIBGroup OBJECT-GROUP
    	OBJECTS {
			alaLFPConfigPort,
			alaLFPConfigPortType,
			alaLFPConfigRowStatus
		}
    	STATUS  current
    	DESCRIPTION
            "A collection of objects to configure a port and port type for a Link Fault Propagation Group."
    	::= { alcatelIND1PortMIBGroups 18 }
	alaPortViolationRecoveryMIBGroup OBJECT-GROUP
    	OBJECTS {			
			alaPortViolationRecoveryTime,
			alaPortViolationRecoveryMaximum
		}
    	STATUS  current
    	DESCRIPTION
            "The per port configuration Parameters for Interface Violation Recovery Mechanism"
    	::= { alcatelIND1PortMIBGroups 19 }
esmSlotInfoGroup OBJECT-GROUP
    OBJECTS { 	esmSlotNumber,
		esmNumberOfUserPorts
	    }
    STATUS current
    DESCRIPTION
            "A collection of objects to provide number of user port information
	    per slot basis."
    ::= { alcatelIND1PortMIBGroups 20 }	
esmConfTrapGroup OBJECT-GROUP
    OBJECTS
    {
    	esmDrvTrapDrops,
       	alaDyingGaspPowerSupplyType,
    	alaDyingGaspSlot,
    	alaDyingGaspTime,
   	esmPortViolationValue,
        esmStormViolationThresholdNotificationType,
        esmStormViolationThresholdTrafficType		
	}
    STATUS current
    DESCRIPTION
            "Specifies the BD type."
    ::= { alcatelIND1PortMIBGroups 21 }	
    alcether10GigGroup OBJECT-GROUP
    OBJECTS
    {
    	alcether10GigPrimary
	}
    STATUS current
    DESCRIPTION
            "populated with the 10 gig only entries."
    ::= { alcatelIND1PortMIBGroups 22 }	
   
    esmHybridConfGroup OBJECT-GROUP
    OBJECTS
    {
    	esmHybridPortCfgCrossover,
    	esmHybridPortCfgDuplexMode,
    	esmHybridPortCfgFlow,
    	esmHybridPortCfgInactiveType,
    	esmHybridPortCfgSFPType,
        esmPortCfgRuntEnable,
        esmPortCfgRuntSize,
        -- esmE2EFlowVlan,
    	esmHybridPortCfgSpeed  ,
    	esmPortCfgHybridActiveType ,
    	esmPortCfgHybridMode,
        esmHybridPortCfgAutoNegotiation
	}
    STATUS current
    DESCRIPTION
            ""
    ::= { alcatelIND1PortMIBGroups 23 }	
        esmPortViolationNotificationGroup NOTIFICATION-GROUP
        NOTIFICATIONS   {
                                esmPortViolation
                     	}
        STATUS  current
        DESCRIPTION
                        "A collection of notifications used to indicate port violation trap."
        ::= { alcatelIND1PortMIBGroups 24 }

   esmStormThresholdViolationGroup NOTIFICATION-GROUP
   NOTIFICATIONS	{
				esmStormThresholdViolationStatus
			}
   STATUS	current
   DESCRIPTION
   "A collection of notifications used to indicate esm storm threshold violation."
   ::= { alcatelIND1PortMIBGroups 26 }
				
    ptpConfigGroup        OBJECT-GROUP 
         OBJECTS { 
                                 ptpConfig
                         } 
         STATUS        current 
         DESCRIPTION 
                         "A collection of objects to allow configuration of PTP." 
         ::=        { alcatelIND1PortMIBGroups 29 }

    esmStackPortConfMIBGroup     OBJECT-GROUP 
         OBJECTS { 
                   esmStackPortIfIndex, esmStackPortSlotNum, esmStackPortInOctets, esmStackPortOutOctets, esmStackPortInUcastPkts, esmStackPortOutUcastPkts,        
                   esmStackPortInMulticastPkts, esmStackPortOutMulticastPkts, esmStackPortInBroadcastPkts, esmStackPortOutBroadcastPkts, esmStackPortInPauseFrames,       
                   esmStackPortOutPauseFrames, esmStackPortStatsAlignmentErrors, esmStackPortStatsFCSErrors, esmStackPortInErrors, esmStackPortOutErrors, esmStackPortInDiscards,          
                   esmStackPortOutDiscards, esmStackPortTxCollisions, esmStackPortRxUndersizePkts, esmStackPortTxUndersizePkts, esmStackPortRxOversizePkts, 
                   esmStackPortTxOversizePkts, esmStackPortAutoSpeed, esmStackPortClearStats
                 } 
         STATUS        current 
         DESCRIPTION 
                         "A collection of objects to support the management of global
            configuration parameters of the stack ports." 
         ::=        { alcatelIND1PortMIBGroups 28 }
END