-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename:   PRVT-RESILIENT-LINK-MIB.mib
-- ** Project:    T - Ethernet and Fast Ethernet IP Switches.
-- ** Purpose:    Private MIB
-- *********************************************************************
-- (c) Copyright, 2001, BATM Advanced Communications.  All rights reserved.
--                             WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information.  This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM.  Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------
--
PRVT-RESILIENT-LINK-MIB DEFINITIONS ::= BEGIN
    IMPORTS
        MODULE-IDENTITY, OBJECT-TYPE, 
        NOTIFICATION-TYPE			      FROM SNMPv2-SMI
        NOTIFICATION-GROUP                FROM SNMPv2-CONF
        switch                            FROM PRVT-SWITCH-MIB;
    -------------------------------------------------------------------------------
    --     PRIVATE BRANCH  PRODUCTS
    -------------------------------------------------------------------------------


    prvtResilientLinkMib MODULE-IDENTITY
        LAST-UPDATED "200502160000Z"
        ORGANIZATION "BATM Advanced Communication"
        CONTACT-INFO   

        "BATM/Telco Systems Support team
				Email: 
				For North America: techsupport@telco.com
				For North Europe: support@batm.de, info@batm.de
				For the rest of the world: techsupport@telco.com"

        DESCRIPTION
        "The Resilient Link MIB module for managing switch or ipSwitch 
         resilient link"

        -- revision history       
         REVISION     "200502160000Z"
     	 DESCRIPTION
		"Fixed spelling errors and changed the contact info." 

		REVISION     "200305060000Z"
		DESCRIPTION
						"Move to SMI-V2."

        REVISION     "200201280000Z"
        DESCRIPTION
                "Initial version."
        ::= { switch 102 }


    -- -----------------------------------------------------------------------------
    -- resilient link configuration parameters
    -- -----------------------------------------------------------------------------
    prvtResilientLinkNotifications  OBJECT IDENTIFIER ::= { prvtResilientLinkMib 0 }
    resilientLinkConfig OBJECT IDENTIFIER ::= { prvtResilientLinkMib 1 }
    resilientLinkStatus             OBJECT IDENTIFIER ::= { prvtResilientLinkMib 2 }
    prvtResilientLinkConformance    OBJECT IDENTIFIER ::= { prvtResilientLinkMib 3 }
    
    resilientLinkConfigTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF ResilientLinkConfigEntry
		MAX-ACCESS	not-accessible
		STATUS	current
		DESCRIPTION
            "This table contains the resilient link configuration."
		::= { resilientLinkConfig 1 }

    resilientLinkConfigEntry 	OBJECT-TYPE
		SYNTAX	ResilientLinkConfigEntry
		MAX-ACCESS	not-accessible
		STATUS	current
		DESCRIPTION
		    "resilientLinkIndex"
        INDEX { resilientLinkIndex }
		::= { resilientLinkConfigTable 1 }

    ResilientLinkConfigEntry ::= SEQUENCE {
        resilientLinkIndex         INTEGER,
        resilientLinkEnable        INTEGER,
        resilientLinkPort1ifIndex  INTEGER,
        resilientLinkPort2ifIndex  INTEGER,
        resilientLinkPreferredPort INTEGER,
        resilientLinkActivePort    INTEGER
    }

    resilientLinkIndex OBJECT-TYPE
        SYNTAX  INTEGER(0..256)
		MAX-ACCESS	read-only
		STATUS	current
		DESCRIPTION            
		    "This object identifies the resilient link" 
		::= { resilientLinkConfigEntry 1 }
    
	resilientLinkEnable OBJECT-TYPE
        SYNTAX  INTEGER	{
                    enable(1),
                    disable(2)
                }
		MAX-ACCESS	read-write
		STATUS	current
		DESCRIPTION
            "This object enables or disables the resilient link"
		::= { resilientLinkConfigEntry 2 }
		
	resilientLinkPort1ifIndex OBJECT-TYPE
        SYNTAX  INTEGER
        	MAX-ACCESS	read-write
		STATUS	current
		DESCRIPTION
            "This object identifies the first port belonging to this
             resilient link; zero means no port is selected"
		::= { resilientLinkConfigEntry 3 }
		
	resilientLinkPort2ifIndex OBJECT-TYPE
        SYNTAX  INTEGER
        	MAX-ACCESS	read-write
		STATUS	current
		DESCRIPTION
            "This object identifies the second port belonging to this
             resilient link; zero means no port is selected"
		::= { resilientLinkConfigEntry 4 }

	resilientLinkPreferredPort OBJECT-TYPE
        SYNTAX  INTEGER
        	MAX-ACCESS	read-write
		STATUS	current
		DESCRIPTION
            "This object identifies the preferred port (1 or 2) in this
             resilient link; zero means no port is preferred"
		::= { resilientLinkConfigEntry 5 }
		
	resilientLinkActivePort OBJECT-TYPE
        SYNTAX  INTEGER
        	MAX-ACCESS	read-write
		STATUS	current
		DESCRIPTION
            "This object identifies the active port (1 or 2) in this
             resilient link. Only ports with link up can be configured as active 
             ports."
		::= { resilientLinkConfigEntry 6 }

    -- -----------------------------------------------------------------------------
    -- resilient link status
    -- -----------------------------------------------------------------------------

    resilientLinkStatusTable 	OBJECT-TYPE
        SYNTAX  SEQUENCE OF ResilientLinkStatusEntry
		MAX-ACCESS	not-accessible
		STATUS	current
		DESCRIPTION
            "This table contains the resilient link status."
		::= { resilientLinkStatus 2 }

    resilientLinkStatusEntry 	OBJECT-TYPE
		SYNTAX	ResilientLinkStatusEntry
		MAX-ACCESS	not-accessible
		STATUS	current
		DESCRIPTION
		    "resilientLinkIndex"
        INDEX { resilientLinkIndex }
		::= { resilientLinkStatusTable 1 }

    ResilientLinkStatusEntry ::= SEQUENCE {
        resilientLinkConnectedPort     INTEGER,
        resilientLinkCurrentActivePort INTEGER
    }

	resilientLinkConnectedPort OBJECT-TYPE
        SYNTAX  INTEGER	{
                    notConnected(1),
                    port1Connected(2),
                    port2Connected(3),
                    port1and2Connected(4)
                }
		MAX-ACCESS	read-only
		STATUS	current
		DESCRIPTION
            "This object shows the connected ports in the resilient link"
		::= { resilientLinkStatusEntry 1 }

	resilientLinkCurrentActivePort OBJECT-TYPE
        SYNTAX  INTEGER {
        		noActivePort (1),
        		port1Active (2),
        		port2Active (3)
        	}
        MAX-ACCESS read-only
		STATUS	current
		DESCRIPTION
            "This object identifies the active port (1 or 2) in this
             resilient link. Only ports with link up can be configured as active 
             ports."
		::= { resilientLinkStatusEntry 2 }
     
     -- Traps for use by prvtResilientLinkMib

     resilientLinkStatusChange NOTIFICATION-TYPE
         OBJECTS { resilientLinkIndex, resilientLinkConnectedPort,
                     resilientLinkCurrentActivePort}
	 STATUS current
         DESCRIPTION
                 "The resilientLinkStatusChange trap indicates that 
                 the sending agent monitor detected a change in the status of the
                 resilient link, identified by resilientLinkIndex."
         ::= {prvtResilientLinkNotifications 1}

-- *******************************************************************
--  Conformance Information
-- *******************************************************************

    prvtResilientLinkMIBGroups       OBJECT IDENTIFIER ::= { prvtResilientLinkConformance 2 }
 
    resilientLinkNotificationGroup NOTIFICATION-GROUP
    	NOTIFICATIONS {
    		resilientLinkStatusChange
    	}
	STATUS current
     	DESCRIPTION
        	"Private Notification Group."
     ::= { prvtResilientLinkMIBGroups 3 }

END